Related Experiment Video
Updated: Jun 28, 2025

Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Cost-effectiveness analysis of the diagnosis of temporal arteritis
Isabel Del Blanco Alonso1, Álvaro Revilla Calavia1, Laura Saiz-Viloria1
1Servicio de Angiología y Cirugía Vascular, Hospital Clínico Universitario de Valladolid, Valladolid, Spain.
Abstract:
Temporal arteritis (TA) is the most common form of systemic vasculitis. Its diagnosis is based on criteria proposed by the American College of Rheumatology (1990), and its treatment is high-dose corticosteroids. Our objective is to assess the cost of diagnosing TA, and secondarily, cost-effective analysis of different diagnostic strategies (clinical, biopsy, doppler ultrasound) and therapeutic strategies (corticosteroid suspension).
Material And Method:
Observational, retrospective study has been carried out on patients with AT (2012-2021). Demographic data, comorbidities, signs and symptoms suggestive of AT were collected. AT was diagnosed with a score ≥ 3 according to American College of Rheumatoloy criteria (ACR-SCORE). The costs of diagnosis and treatment modification were analysed.
Results:
Seventy-five patients have been included, median age 77 (46-87) years. Headache, temporal pain and jaw claudication were significant for the diagnosis of TA. Patients with a halo on Doppler ultrasound and a positive biopsy have significantly elevated ESR and CRP compared to patients who do not. The cost of the AT diagnosis was 414.7 euros/patient. If we use ACR-SCORE ≥ 3-echodoppler it is 167.2 є/patient (savings 59.6%) and ACR-SCORE ≥ 3-biopsy 339.75 є/patient (savings 18%). If the corticosteroid was removed and a biopsy was performed, 21.6 є/patient (94.7% savings), if the corticosteroid was removed and Doppler ultrasound was performed, 10.6 є/patient (97.4% savings).
Conclusions:
Headache, temporary pain and jaw claudication are predictors of AT. Elevated ESR and CRP are predictors of positive biopsy and presence of halo on ultrasound. The uses of ACR-SCORE ≥ 3 with Doppler ultrasound or biopsy, and with corticosteroid suspension, are cost-effective.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...