Related Experiment Video
Updated: Jun 28, 2025

Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
Simple Determination of Bosentan in Plasma Samples by Reversed-Phase High-Performance Liquid Chromatography
1Biotechnology and Medicinal Plants Research Center, Ilam University of Medical Sciences, Ilam, Iran.
Background:
In order to measure the plasma levels of Losartan and Bosentan, a sensitive Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) technique was developed.
Methods:
To compare bioavailability, the Area Under the Curve (AUC), peak plasma concentration (Cmax), and time to Cmax (Tmax) were employed. The standard curve (150-2400 ng/ml) was linear (R2=0.999), relative errors were between 2.4 to 10.05% and the coefficient of variation (CV%) ranged from 1.52 to 10.88. A single dosage (test and reference) was used for the in vivo investigation, which involved 16 healthy individuals.
Results:
The AUC0-48, AUC0-, Cmax, and Tmax of the test and reference had no statistically significant differences. The Cmax and 95% confidence intervals of the ratio of Cmax of the two formulations were 0.93-0.96 and 97.6-135%, respectively.
Conclusion:
Therefore, it was established that generic Bosentan was equivalent to Bosentan from Actelion and that both medications could be regarded as equally effective in clinical settings. The blood level of Bosentan could be measured using this straightforward procedure in all hospital laboratories.