Context:
Medical devices fall under the broad topic encompass everything from basic hardware to integrated software systems. The integration of software into hardware devices is not simple due to requirements of regional regulatory bodies. Therefore, medical businesses need to oversee not only the creation of devices but also the observance of guidelines and standards established by regulatory bodies. While plan-driven methodologies prevented software from evolving or changing, agile methodologies have inherent characteristics of insufficient planning and documentation.
Objectives:
The objective of our research is to propose a suitable process model for medical device development, keeping in mind the regulatory requirements.
Methods:
First, based on the detailed analysis of literature and McHughs proposed model, we suggested the Enhanced Agile V-Model (EAV), which combines plan-driven and agile approaches. Second, we mapped the proposed model to the MDEVSPICE framework to confirm that it adhered to the rules outlined in the standard IEC62304. Finally, the proposed model is evaluated through implication to case study of wave therapeutic medical device.
Results:
The support of both agile and waterfall approach in EAV model helps in accommodating new requirements in the medical devices and the proposed systems engineering approach helps in hardware and software integration. The mapping of the EAV model to the MDEVSPICE shows complete compliance. Moreover, the implication of the proposed model has been clearly shown statistically and successfully implemented in our case study. Further, device usability and efficiency metrics showed confidence of P < 0.05 and for device safety and efficiency, we conducted an experiment which shows significant improvement in selected parameters.
Conclusion:
The proposed model shows conformance to regulatory standards, and successfully implemented in development of wave therapeutic device. However, its applicability to more compact and straightforward medical products is unknown and can be determined by using this model to analyze the performance of other medical products.
Related Concept Videos
Methods of Documentation VI: Case Management Model
For example, a patient with a chronic...
Preclinical Development: Overview
Drug Regulation
Methods Of Healthcare Delivery System
Managed Care System:
The managed care system is designed to control the cost while maintaining the quality of care. The patient's care from admission to discharge is planned by the primary care provider or the case manager, also known as the gatekeeper. In a managed care system, the number of care providers is...
Healthcare Agencies II
Parish nursing is a growing specialty nursing profession that focuses on holistic healthcare, health promotion, and illness prevention. It blends professional nursing practice with a health ministry, focusing on health and healing within the context of a Christian community. Parish nurses serve as health educators, referral sources,...
Methods of Documentation VII: EMR