Effectiveness of low dose computed tomography to detect fractures in paediatric suspected physical abuse: a
Edel Doyle1, Lyndal Bugeja2, Matthew R Dimmock3,4
1Department of Forensic Medicine, Monash University, 65 Kavanagh Street, Southbank, VIC, 3004, Australia. edel.doyle@monash.edu.
Purpose:
The skeletal survey X-ray series is the current 'gold standard' when investigating suspected physical abuse (SPA) of children, in addition to a non-contrast computed tomography (CT) brain scan. This systematic literature review synthesised findings of published research to determine if low dose computed tomography (LDCT) could detect subtle fractures and therefore replace the skeletal survey X-ray series in the investigation of SPA in children aged under 3 years.
Methods:
Five electronic databases and grey literature were systematically searched from their inception to 28 April 2022. Primary studies were included where the population comprised paediatric patients up to 16 years and LDCT was used to detect fractures associated with SPA. Studies involving imaging investigations of the head, standard dose CT examinations or accidental trauma were excluded.
Results:
Three studies met the inclusion criteria, all of which were case series. These studies did not report many of the criteria required to compare the accuracy of LDCT to X-ray, i.e. they did not meet the criteria for a diagnostic accuracy test. Therefore, it is difficult to conclude from the case series if LDCT is accurate enough to replace X-rays.
Conclusion:
Due to the gap in current literature, a phantom study and subsequent post-mortem CT study are recommended as the primary investigative methods to assess the ability of low-dose CT to identify the subtle fractures associated with SPA and to calculate how low the achievable CT dose can be.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Radiological Investigation I: X-ray and CT
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...