Home Pulse Oximetry Monitoring during the COVID-19 Pandemic: An Assessment of Patient Engagement and Compliance
R Gentry Wilkerson1, Youssef Annous1, Eli Farhy1
1Department of Emergency Medicine, University of Maryland School of Medicine, 110 S. Paca Street, 6th Floor, Suite 200, Baltimore, MD 21201.
Objectives:
Patients with suspected COVID-19 remain at risk for clinical deterioration after discharge and may benefit from home oxygen saturation (SpO2) monitoring using portable pulse oximeter devices. Our study aims to evaluate patient engagement and compliance with a home SpO2 monitoring program.
Methods:
This is a single center, prospective pilot study of patients being discharged from the ED or urgent care after evaluation of symptoms consistent with COVID-19. Subjects were given a portable pulse oximeter and instructed to obtain measurements at rest and with exertion twice daily for 14 days. Patients were contacted daily to collect recorded data. If attempts to contact the patient were unsuccessful for 3 consecutive days, patients were considered lost to follow up. The primary outcome of interest was patient engagement in the program which was defined as the percentage of patients that completed the 14-day study period, meaning they were not lost to follow up. Secondary outcomes included compliance with performing the SpO2 readings. Patient compliance was calculated as a percentage of completed readings out of the total expected readings.
Results:
Fifty patients were enrolled - 2 withdrew and 1 was a screen failure. Overall, engagement in the program was 46.8% with no significant difference between those who tested positive for SARS-CoV-2 versus those who tested negative (48.2% vs 45%, p = 0.831). Median compliance overall was 42.9% (IQR 22.22-78.57). Median compliance for the positive group was 50.0% (IQR 20-85.71) and 42.86% (IQR 22.92-76.44) for the negative group (p= 0.838).
Conclusion:
Our study demonstrated that there was acceptable engagement and compliance in a 14-day home SpO2 monitoring program. These results support the use of home pulse oximetry monitoring in a select group of mildly ill patients with suspected COVID-19.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Special considerations while measuring pulse