Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

5.1K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
5.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Predicting the Degree of Coronary Artery Stenosis Through Retinal Vascular Characteristics and Minimal Clinical Information.

International journal of general medicine·2025
Same author

Atomic Hydrogen in Hydrogenolysis: Converting and Detoxifying Carbon-Heteroatom Bonds via Paired Electrolysis.

Environmental science & technology·2025
Same author

FAM210B activates STAT1/IRF9/IFIT3 axis by upregulating IFN-α/β expression to impede the progression of lung adenocarcinoma.

Cell death & disease·2025
Same author

Discovery of Fluorescent Probe ABDS-2 for Farnesoid X Receptor Modulator Characterization and Cell-Based Imaging.

Analytical chemistry·2025
Same author

DNA-compatible one-pot synthesis of multi-substituted dihydrofuran <i>via</i> pyridinium ylide-mediated cyclization.

Organic & biomolecular chemistry·2025
Same author

The Evolution of Nucleic Acid Nanotechnology: From DNA Assembly to DNA-Encoded Library.

Small methods·2025

Related Experiment Video

Updated: Jun 28, 2025

Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
08:19

Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences

Published on: May 17, 2018

9.8K

Detunable wireless resonator arrays for TMJ MRI: A comparative study.

Haoqin Zhu1, Qiang Zhang2, Rangsong Li3

  • 1Sino Canada Health Institute Inc., Winnipeg, Manitoba, Canada.

Magnetic Resonance Imaging
|April 15, 2024
PubMed
Summary

This study enhances temporomandibular joint magnetic resonance imaging (TMJ MRI) for diagnosing temporomandibular disorders (TMDs). A novel 3-loop wireless coil design significantly improves signal-to-noise ratio (SNR) for clearer TMJ imaging.

Keywords:
ArrayDetuneMRIRF coilTMJWireless coil

More Related Videos

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
15:48

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging

Published on: December 15, 2014

22.5K
Repetitive Transcranial Magnetic Stimulation to the Unilateral Hemisphere of Rat Brain
05:47

Repetitive Transcranial Magnetic Stimulation to the Unilateral Hemisphere of Rat Brain

Published on: October 22, 2016

12.5K

Related Experiment Videos

Last Updated: Jun 28, 2025

Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
08:19

Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences

Published on: May 17, 2018

9.8K
Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
15:48

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging

Published on: December 15, 2014

22.5K
Repetitive Transcranial Magnetic Stimulation to the Unilateral Hemisphere of Rat Brain
05:47

Repetitive Transcranial Magnetic Stimulation to the Unilateral Hemisphere of Rat Brain

Published on: October 22, 2016

12.5K

Area of Science:

  • Medical Imaging
  • Biomedical Engineering
  • Radiology

Background:

  • Temporomandibular disorders (TMDs) require accurate diagnosis.
  • Temporomandibular Joint Magnetic Resonance Imaging (TMJ MRI) is essential for diagnosing TMDs.
  • Existing TMJ MRI techniques can be limited by image quality and coil complexity.

Purpose of the Study:

  • To investigate and optimize wireless coil configurations for enhanced TMJ MRI.
  • To evaluate the signal-to-noise ratio (SNR) of different wireless coil designs.
  • To develop a more effective and comfortable TMJ MRI solution.

Main Methods:

  • Investigated multiple inductively coupled wireless coil configurations for TMJ MRI.
  • Tested 1-loop (9 cm diameter), 2-loop (7 cm diameter each), and 3-loop (5 cm diameter each) designs.
  • Assessed coil performance, focusing on signal-to-noise ratio (SNR) and visualization capabilities.

Main Results:

  • The 3-loop wireless coil configuration demonstrated the optimal signal-to-noise ratio (SNR).
  • Bilateral deployment of wireless coils further amplified SNR, enhancing TMJ structure visualization.
  • The detunable wireless coil design is cost-effective, comfortable, and requires no system parameter adjustments.

Conclusions:

  • The 3-loop wireless coil design significantly improves TMJ MRI quality.
  • This optimized wireless coil technology enhances diagnostic accuracy for TMDs.
  • The solution offers broad MRI platform adaptability for routine clinical use.