Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Risk prediction of pulse wave for hypertensive target organ damage based on frequency-domain feature map
Jingdong Yang1, Jiangtao Lü1, Zehao Qiu1
1Autonomous Robot Lab, School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Abstract:
The application of deep learning to the classification of pulse waves in Traditional Chinese Medicine (TCM) related to hypertensive target organ damage (TOD) is hindered by challenges such as low classification accuracy and inadequate generalization performance. To address these challenges, we introduce a lightweight transfer learning model named MobileNetV2SCP. This model transforms time-domain pulse waves into 36-dimensional frequency-domain waveform feature maps and establishes a dedicated pre-training network based on these maps to enhance the learning capability for small samples. To improve global feature correlation, we incorporate a novel fusion attention mechanism (SAS) into the inverted residual structure, along with the utilization of 3 × 3 convolutional layers and BatchNorm layers to mitigate model overfitting. The proposed model is evaluated using cross-validation results from 805 cases of pulse waves associated with hypertensive TOD. The assessment metrics, including Accuracy (92.74 %), F1-score (91.47 %), and Area Under Curve (AUC) (97.12 %), demonstrate superior classification accuracy and generalization performance compared to various state-of-the-art models. Furthermore, this study investigates the correlations between time-domain and frequency-domain features in pulse waves and their classification in hypertensive TOD. It analyzes key factors influencing pulse wave classification, providing valuable insights for the clinical diagnosis of TOD.
Related Concept Videos
Blood Pressure
Special considerations while measuring pulse
Pulse
The pulse serves as a clinical...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...