Related Experiment Video
Updated: Jun 28, 2025

A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering
Published on: December 7, 2016
Estimation of haemoglobin using non-invasive portable device with spectroscopic signal application
A M Amrutha1, Bhagyalaxmi Sidenur2, Balu P S3
1Department of Community Medicine, Basaveshwara Medical College and Hospital, Chitradurga, India.
Abstract:
An estimated 52% of non-pregnant women of reproductive age in India are estimated to be affected by anaemia, which is categorised as a chronic condition. In 2019-2021, the National Family Health Survey-5 (NFHS-5) which was undertaken revealed the following statistics about the prevalence of anaemia in the state of Karnataka. To estimate haemoglobin levels using non-invasive portable device among nursing students. A cross sectional study was done among students of Nursing college in central Karnataka for a period of 3 months. Total of 140 students were included in the study. EzeCheck haemoglobin estimation was done twice and was recorded in the same Google form. The frequency and percentage of variation of results between Haematology Analyzer and EzeCheck devices was presented with a range of difference such as 0, less than 1, 1.0 to 1.9, 2.0 to 2.9, 3.0 to 3.9, and 4.0 and above. The total prevalence of anaemia among nursing students was 57.8% and most of the students had moderate degree of anaemia (28.6%). Two readings of haemoglobin were taken and difference of readings were calculated and majority of the students had difference of < 0.5 gm/dl (61.4%) and only 1.4% of the students had difference of > 2 gm/dl. The mean difference of haemoglobin of two readings was 0.5 ± 0.5 gm/dl. The technology employed in this study bridges the gap between patients and anaemia diagnosis by providing screening services. The device provides the diagnosis via a non-invasive, IoT-enabled service at a low cost.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:24A Precision Medicine Tool for Measurement and Monitoring of Hemoglobin S in Sickle Cell Disease Patients Receiving Transfusion Therapy
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...