Pure Vision Transformer (CT-ViT) with Noise2Neighbors Interpolation for Low-Dose CT Image Denoising
Luella Marcos1, Paul Babyn2, Javad Alirezaie3
1Department of Electrical, Biomedical and Computer Engineering, Toronto Metropolitan University (formerly Ryerson University), 350 Victoria Street, Toronto, M5B 2K3, Ontario, Canada.
Abstract:
Convolutional neural networks (CNN) have been used for a wide variety of deep learning applications, especially in computer vision. For medical image processing, researchers have identified certain challenges associated with CNNs. These challenges encompass the generation of less informative features, limitations in capturing both high and low-frequency information within feature maps, and the computational cost incurred when enhancing receptive fields by deepening the network. Transformers have emerged as an approach aiming to address and overcome these specific limitations of CNNs in the context of medical image analysis. Preservation of all spatial details of medical images is necessary to ensure accurate patient diagnosis. Hence, this research introduced the use of a pure Vision Transformer (ViT) for a denoising artificial neural network for medical image processing specifically for low-dose computed tomography (LDCT) image denoising. The proposed model follows a U-Net framework that contains ViT modules with the integration of Noise2Neighbor (N2N) interpolation operation. Five different datasets containing LDCT and normal-dose CT (NDCT) image pairs were used to carry out this experiment. To test the efficacy of the proposed model, this experiment includes comparisons between the quantitative and visual results among CNN-based (BM3D, RED-CNN, DRL-E-MP), hybrid CNN-ViT-based (TED-Net), and the proposed pure ViT-based denoising model. The findings of this study showed that there is about 15-20% increase in SSIM and PSNR when using self-attention transformers than using the typical pure CNN. Visual results also showed improvements especially when it comes to showing fine structural details of CT images.
Related Concept Videos
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Downsampling
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Trimmed Mean
Although certain measures of central tendency are not sensitive to outliers, there are alternative versions of the mean that get around the...