Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Auricular compression stent.

V A Chalian, J E Bennett, A M Sayoc

    The Journal of Prosthetic Dentistry
    |October 1, 1985
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Immune-globulin prophylaxis of respiratory syncytial virus infection in patients undergoing stem-cell transplantation.

    The Journal of infectious diseases·2002
    Same author

    Defining opportunistic invasive fungal infections in immunocompromised patients with cancer and hematopoietic stem cell transplants: an international consensus.

    Clinical infectious diseases : an official publication of the Infectious Diseases Society of America·2001
    Same author

    Outbreak of human parainfluenza virus 3 infections in a hematopoietic stem cell transplant population.

    The Journal of infectious diseases·2001
    Same author

    Factors contributing to the development of medial tibial stress syndrome in high school runners.

    The Journal of orthopaedic and sports physical therapy·2001
    Same author

    Need for alternative trial designs and evaluation strategies for therapeutic studies of invasive mycoses.

    Clinical infectious diseases : an official publication of the Infectious Diseases Society of America·2001
    Same author

    CMV reactivation in nonmyeloablative HSCT.

    Bone marrow transplantation·2001
    Same journal

    Effects of prosthetic screw modifications and tightening conditions on mechanical outcomes in screw-retained implant restorations: A systematic review and meta-analysis of in vitro studies.

    The Journal of prosthetic dentistry·2026
    Same journal

    Influence of silane-containing universal adhesives and separate silanization on lithium disilicate bond strength.

    The Journal of prosthetic dentistry·2026
    Same journal

    Clinical, radiographic, and esthetic outcomes of the socket shield technique versus conventional postextraction implant placement: A systematic review.

    The Journal of prosthetic dentistry·2026
    Same journal

    Response to Letter to the Editor regarding, "Dimensional accuracy and clinical adaptation of monolithic zirconia crowns…" and "Effect of finish line designs on the dimensional accuracy of monolithic zirconia crowns".

    The Journal of prosthetic dentistry·2026
    Same journal

    Risk factors in peri-implantitis: A narrative review.

    The Journal of prosthetic dentistry·2026
    Same journal

    Vat photopolymerization-printed zirconia veneered with porcelain: Mechanical properties, fatigue properties, and fractographic analysis.

    The Journal of prosthetic dentistry·2026
    See all related articles

    A new auricular compression stent provides uniform, adjustable pressure after earlobe keloid surgery. This two-component device, made of acrylic resin and nylon screws, aids in post-operative recovery.

    Area of Science:

    • Plastic and Reconstructive Surgery
    • Biomedical Engineering
    • Dermatology

    Background:

    • Keloids are common benign skin tumors that can develop on the earlobe after injury.
    • Post-surgical management of earlobe keloids often requires sustained compression to prevent recurrence.
    • Existing compression methods may lack uniformity or adjustability, potentially impacting treatment efficacy.

    Purpose of the Study:

    • To introduce a novel auricular compression stent designed for earlobe keloid treatment.
    • To provide a device capable of maintaining uniform and adjustable compression post-surgery.
    • To assess the potential of this stent in improving outcomes for earlobe keloid patients.

    Main Methods:

    • Development of a two-component device using heat-polymerized acrylic resin.

    Related Experiment Videos

  • Assembly of the stent components utilizing nylon screws for adjustability.
  • Application of the stent for post-operative compression following earlobe keloid excision.
  • Main Results:

    • The developed stent facilitates consistent and customizable compression on the earlobe.
    • The acrylic resin material offers a biocompatible and durable structure.
    • The screw mechanism allows for precise adjustment of compression levels.

    Conclusions:

    • The auricular compression stent represents a promising tool for managing earlobe keloids.
    • Its design allows for tailored compression, potentially reducing recurrence rates.
    • Further clinical evaluation is warranted to confirm long-term efficacy and patient satisfaction.