Related Experiment Video
Updated: Jun 28, 2025

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Conventional and digital maxillary occlusal record for the manufacture of complete-arch implant-supported fixed
Ana Larisse Carneiro Pereira1, Maria de Fátima Trindade Pinto Campos1, Ana Clara Soares Paiva Torres2
1Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), AV. Senador Salgado Filho, 1787, Lagoa Nova, Natal, Rio Grande do Norte, 59056-000, Brazil.
Objectives:
To evaluate the trueness of the digital maxillary occlusal records in comparison with the conventional records for the fabrication of complete-arch implant-supported fixed prostheses.
Materials And Methods:
This randomized controlled clinical trial followed the recommendations of the CONSORT statement. Twenty participants who used a mandibular interim complete-arch fixed prosthesis and conventional complete maxillary dentures were included in the study. The participants were randomized into two types of maxillary occlusal records: conventional (COR) and digital (DOR) (TRIOS; Shape A/S). After fabricating the prostheses, the distribution and number of occlusal contact points, and the time taken to obtain the maxillary occlusal record and work model were evaluated. Descriptive analysis was used to evaluate the distribution of occlusal contact points. The Wilcoxon test was employed for assessing the number of occlusal contact points, while the Mann-Whitney U test was used for the time taken to obtain the working casts and the maxillary occlusal record and occlusal adjustment times (p < 0.05).
Results:
There was a similarity in the jaw relation recording methods regarding the distribution of occlusal contact points. There was no difference in the number of occlusal contact points between the anterior (p = 0.439) and posterior (p = 0.227) teeth. No relationship was observed between the distribution and number of occlusal contact points (COR, p = 0.288; DOR, p = 0.183). DOR required less occlusal and clinical adjustment time, on the other hand more laboratory and total workflow time than COR (p < 0.001).
Conclusion:
The DOR may be an option for obtaining the functional space necessary for the assembly of teeth in complete-arch implant-supported fixed prostheses; however, it requires more working time.
Clinical Relevance:
The digital occlusal recording method can be used to assess the interocclusal space for the virtual tooth setup of a complete-arch implant-supported fixed prosthesis.