Analysis of gait pattern related to high cerebral small vessel disease burden using quantitative gait data from
Kelin Xu1, Yingzhe Wang2, Yanfeng Jiang3
1Department of Biostatistics, Ministry of Education Key Laboratory of Public Health Safety, School of Public Health, Fudan University, Shanghai, China.
Background And Objectives:
Sensor-based wearable devices help to obtain a wide range of quantitative gait parameters, which provides sufficient data to investigate disease-specific gait patterns. Although cerebral small vessel disease (CSVD) plays a significant role in gait impairment, the specific gait pattern associated with a high burden of CSVD remains to be explored.
Methods:
We analyzed the gait pattern related to high CSVD burden from 720 participants (aged 55-65 years, 42.5 % male) free of neurological disease in the Taizhou Imaging Study. All participants underwent detailed quantitative gait assessments (obtained from an insole-like wearable gait tracking device) and brain magnetic resonance imaging examinations. Thirty-three gait parameters were summarized into five gait domains. Sparse sliced inverse regression was developed to extract the gait pattern related to high CSVD burden.
Results:
The specific gait pattern derived from several gait domains (i.e., angles, phases, variability, and spatio-temporal) was significantly associated with the CSVD burden (OR=1.250, 95 % CI: 1.011-1.546). The gait pattern indicates that people with a high CSVD burden were prone to have smaller gait angles, more stance time, more double support time, larger gait variability, and slower gait velocity. Furthermore, people with this gait pattern had a 25 % higher risk of a high CSVD burden.
Conclusions:
We established a more stable and disease-specific quantitative gait pattern related to high CSVD burden, which is prone to facilitate the identification of individuals with high CSVD burden among the community residents or the general population.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...