Characterizing a visual lateral flow device for rapid SARS-CoV-2 virus protein detection: pre-clinical and system
Natpapas Wiriyachaiporn1, Jetnapang Kongrueng1, Kannika Sukkuea1
1National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), Pathum Thani, 12120, Thailand. natpapas@nanotec.or.th.
None:
Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infections have affected more than 769 million individuals worldwide over the last few years. Although the pandemic is transitioning into an endemic, the COVID-19 outbreak is still a global concern. A rapid screening platform is needed for effective preventive and control measures. Herein, a visual rapid lateral flow platform for SARS-CoV-2 nucleocapsid protein detection is developed. Under optimal conditions, the system demonstrated good detection sensitivity and selectivity against tested respiratory viruses. The system provides direct visual detection with a limit of 0.7 ng of the nucleocapsid protein per mL of a sample (0.7 ng mL-1) within 15 minutes. Further, a correlation between direct visual detection and semi-quantitative analysis using a reader showed a similar detection limit (R2 = 0.9571). The repeatability and reproducibility studies highlighted the potential of the system for the rapid screening of SARS-CoV-2 infection, with variations within 5% and 10% at high and low protein concentrations, respectively. Subsequent pre-clinical validation to correlate the performance with the standard molecular approach (RT-PCR) using 170 nasopharyngeal swabs demonstrated 98% estimated sensitivity (95% CI, 89.35-99.95%) and 100% specificity (95% CI, 96.38-100%). The positive and negative predictive values were reported to be 100% and 99%, respectively, with an accuracy of 99.3%. With high viral load samples (Ct value ≤25, n = 47), the system demonstrated 100% detection sensitivity and specificity. The proposed technique provides a valuable platform for potential use in rapid screening, particularly during pandemics, where diagnostic capacity and mass screening are crucial.
More Related Videos
10:10Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
07:13Author Spotlight: High-Quality Quantum Dot Nanobeads for Sensitive Fluorescent Lateral Flow Immunoassays
Published on: June 28, 2024