Related Experiment Video
Updated: Jun 28, 2025

E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Validation of artificial intelligence-based bowel preparation assessment in screening colonoscopy (with video)
Liwen Yao1, Huizhen Xiong2, Qiucheng Li2
1Gastrointestinal Endoscopy Center, The Eighth Affiliated Hospital, Sun Yat-sen University, Shenzhen, China; Key Laboratory of Hubei Province for Digestive System Disease, Renmin Hospital of Wuhan University, Wuhan, China.
Background And Aims:
Accurate bowel preparation assessment is essential for determining colonoscopy screening intervals. Patients with suboptimal bowel preparation are at a high risk of missing >5 mm adenomas and should undergo an early repeat colonoscopy. In this study, we used artificial intelligence (AI) to evaluate bowel preparation and validated the ability of the system to accurately identify patients who are at high risk of having >5 mm adenomas missed due to inadequate bowel preparation.
Methods:
This prospective, single-center, observational study was conducted at the Eighth Affiliated Hospital, Sun Yat-sen University, from October 8, 2021, to November 9, 2022. Eligible patients who underwent screening colonoscopy were consecutively enrolled. The AI assessed bowel preparation using the e-Boston Bowel Preparation Scale (e-BBPS) while endoscopists made evaluations using BBPS. If both BBPS and e-BBPS deemed preparation adequate, the patient immediately underwent a second colonoscopy; otherwise, the patient underwent bowel re-cleansing before the second colonoscopy.
Results:
Among the 393 patients, 72 adenomas >5 mm in size were detected; 27 adenomas >5 mm in size were missed. In unqualified-AI patients, the >5 mm adenoma miss rate (AMR) was significantly higher than in qualified-AI patients (35.71% vs 13.19% [P = .0056]; odds ratio [OR], .2734 [95% CI, .1139-.6565]), as were the AMR (50.89% vs 20.79% [P < .001]; OR, .2532 [95% CI, .1583-.4052]) and >5 mm polyp miss rate (35.82% vs 19.48% [P = .0152]; OR, .4335 [95% CI, .2288-.8213]).
Conclusions:
This study confirmed that patients classified as inadequate by AI exhibited an unacceptable >5 mm AMR, providing key evidence for implementing AI in guiding bowel re-cleansing and potentially standardizing future colonoscopy screening. (Clinical trial registration number: NCT05145712.).
More Related Videos
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Endoscopic Procedures II: Colonoscopy
Serum Laboratory Studies, Stool Test, Breath Test
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Inflammatory Bowel Disease III: Diagnostic Studies and Management I-Nutritional Therapy
Diagnostic studies
A colonoscopy is the definitive screening test, distinguishing ulcerative colitis from other colon diseases with similar symptoms. During a colonoscopy test, inflamed mucosa with exudate ulcerations can be observed, and biopsies are taken to determine the histologic characteristics of the...