Related Experiment Video
Updated: Jun 28, 2025

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Comparison of non-contrast abbreviated MRI and ultrasound as surveillance modalities for HCC
Dong Hwan Kim1, Jeong Hee Yoon2, Moon Hyung Choi3
1Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul 06591, Republic of Korea; Current address: Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-Ro 43-Gil, Songpa-Gu, Seoul 05505, Republic of Korea.
Background & Aims:
Ultrasound (US) is recommended for HCC surveillance in high-risk patients but has limited performance in detecting early-stage HCC. We aimed to compare the diagnostic performance of biannual US and annual non-contrast abbreviated magnetic resonance imaging (NC-AMRI) as HCC surveillance modalities in high-risk patients.
Methods:
This prospective, multicenter cohort study enrolled participants with an estimated annual risk of HCC greater than 5% between October 2015 and April 2017. Participants underwent six rounds of HCC surveillance at 6-month intervals, with both US and NC-AMRI at rounds 1, 3, and 5, and only US at rounds 2, 4, and 6. The sensitivity, diagnostic yield (DY), and false referral rate (FRR) for HCC detection by US and NC-AMRI were compared.
Results:
In total, 208 participants underwent 980 US and 516 NC-AMRI examinations during 30 months of follow-up. Among them, 34 HCCs were diagnosed in 31 participants, with 20 (64.5%) classified as very early-stage and 11 (35.5%) as early-stage HCC. The sensitivity of annual NC-AMRI (71.0%, 22/31) was marginally higher than that of biannual US (45.2%, 14/31; p = 0.077). NC-AMRI showed a significantly higher DY than US (4.26% vs. 1.43%, p <0.001), with a similar FRR (2.91% vs. 3.06%, p = 0.885). A simulation of alternating US and NC-AMRI at 6-month intervals yielded a sensitivity of 83.9% (26/31), significantly exceeding that of biannual US (p = 0.006).
Conclusions:
Annual NC-AMRI showed a marginally higher sensitivity than biannual US for HCC detection in high-risk patients. The DY of annual NC-AMRI was significantly higher than that of biannual US, without increasing the FRR. Thus, alternating US and NC-AMRI at 6-month intervals could be an optimal surveillance strategy for high-risk patients.
Impact And Implications:
Current guidelines permit the use of magnetic resonance imaging (MRI) as a surveillance tool for hepatocellular carcinoma in patients in whom ultrasonography (US) is inadequate. However, the specific indications, imaging sequences, and intervals for MRI surveillance remain unclear. In our study, we found that annual non-contrast abbreviated MRI exhibited marginally higher sensitivity and significantly better diagnostic yield than biannual US in patients at high risk of hepatocellular carcinoma. Alternating US and non-contrast abbreviated MRI at 6-month intervals led to significantly improved sensitivity compared to biannual US, making it a potentially optimal surveillance strategy for high-risk patients.
Gov Identifier:
NCT02551250.
More Related Videos
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...