Related Experiment Video
Updated: Jun 23, 2026

SSVEP-based Experimental Procedure for Brain-Robot Interaction with Humanoid Robots
Published on: November 24, 2015
An SSVEP-based BCI with 112 targets using frequency spatial multiplexing
Yaru Liu1, Wei Dai1, Yadong Liu1
1College of Intelligence Science and Technology, National University of Defense Technology, Changsha 410000, People's Republic of China.
Abstract:
Objective.Brain-computer interface (BCI) systems with large directly accessible instruction sets are one of the difficulties in BCI research. Research to achieve high target resolution (⩾100) has not yet entered a rapid development stage, which contradicts the application requirements. Steady-state visual evoked potential (SSVEP) based BCIs have an advantage in terms of the number of targets, but the competitive mechanism between the target stimulus and its neighboring stimuli is a key challenge that prevents the target resolution from being improved significantly.Approach.In this paper, we reverse the competitive mechanism and propose a frequency spatial multiplexing method to produce more targets with limited frequencies. In the proposed paradigm, we replicated each flicker stimulus as a 2 × 2 matrix and arrange the matrices of all frequencies in a tiled fashion to form the interaction interface. With different arrangements, we designed and tested three example paradigms with different layouts. Further we designed a graph neural network that distinguishes between targets of the same frequency by recognizing the different electroencephalography (EEG) response distribution patterns evoked by each target and its neighboring targets.Main results.Extensive experiment studies employing eleven subjects have been performed to verify the validity of the proposed method. The average classification accuracies in the offline validation experiments for the three paradigms are 89.16%, 91.38%, and 87.90%, with information transfer rates (ITR) of 51.66, 53.96, and 50.55 bits/min, respectively.Significance.This study utilized the positional relationship between stimuli and did not circumvent the competing response problem. Therefore, other state-of-the-art methods focusing on enhancing the efficiency of SSVEP detection can be used as a basis for the present method to achieve very promising improvements.
Related Concept Videos
IR Frequency Region: Fingerprint Region
The...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Pilot and Numeric Relaying