Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
A Direct Assessment of Noninvasive Continuous Blood Pressure Monitoring in the Emergency Department and Intensive
Introduction:
Noninvasive continuous blood pressure monitoring has the potential to improve patient treatment in the hospital setting. Such noninvasive devices can be applied earlier in the treatment process to empower nurses and clinicians to react more quickly to patient deterioration with the added benefit of eliminating the risks associated with invasive monitoring. However, emerging technologies must be capable of reproducing current clinical measures for medical decision making.
Methods:
This study aimed to determine the usability and willingness of nurses to implement a noninvasive continuous blood pressure monitoring device. The secondary aim directly compared the systolic blood pressure, diastolic blood pressure, and mean arterial pressure values recorded by the device (VitalStream; CareTaker Medical LLC, Charlottesville, VA) with the "gold standard" brachial cuff and arterial line measures recorded in the emergency department and intensive care unit settings.
Results:
VitalStream was similarly received by nurses in the emergency department and intensive care setting, but ultimately had greater promotion from emergency nurses. Despite some statistical similarity between measurement methodologies, all direct comparisons were found to not meet the Association for the Advancement of Medical Instrumentation 2008 and Association for the Advancement of Medical Instrumentation / European Society of Hypertension / International Organization for Standardization 2019 consensus statement criteria for acceptable blood pressure measure differences between the VitalStream and "gold standard" clinical measures. In all instances, the standard deviation of the Bland-Altman bias exceeded 8 mm Hg with less than 85% of paired differences falling within 10 mm Hg of the "gold standard."
Discussion:
Taken together, the tested device requires additional postprocessing for medical decision making in trauma or emergent care.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)