Related Experiment Video
Updated: Jun 28, 2026

Implantation of the Syncardia Total Artificial Heart
Published on: July 18, 2014
Temporal Analysis in Outcomes of Long-Term Mechanical Circulatory Support: Retrospective Study
Matej Ondrusek1, Panagiotis Artemiou1, Branislav Bezak1
1Faculty of Medicine of the Comenius University, National Institute of Cardiovascular diseases, Clinic of Cardiac Surgery, Bratislava, Slovakia.
Background:
Mechanical assist device indications have changed in recent years. Reduced incidence of complications, better survival, and the third generation of mechanical support devices contributed to this change. In this single-center study, we focused on two time periods that are characterized by the use of different types of mechanical support devices, different patient characteristics, and change in the indications.
Methods:
The data were processed from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). We retrospectively defined two time intervals to reflect changes in ventricular assist device technology (period 1: 2007-2015; period 2: 2016-20222). A total of 181 patients underwent left ventricular assist device implantation. Device utilization was the following: HeartMate II = 52 (76.4%) and HeartWare = 16 (23.6%) in period 1 and HeartMate II = 2 (1.8%), HeartMate 3 = 70 (61:9%), HeartWare = 29 (25.7%), SynCardia TAH = 10 (8.8%), and BerlinHeart EXCOR = 2 (1.8%) in period 2. The outcomes of the time intervals were analyzed and evaluated.
Results:
Survival was significantly higher during the second time period. Multivariate analysis revealed that age and bypass pump time are independent predictors of mortality. Idiopathic cardiomyopathy, bypass time, and the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) score are independent predictors of adverse events. Furthermore, the first period was noted to be at an increased risk of the following adverse events: pump thrombosis, gastrointestinal bleeding, and bleeding events.
Conclusion:
Despite the higher risk profile of the patients and persistent challenges, during the second period, there was a significant decrease in mortality and morbidity. The use of the HeartMate 3 device may have contributed to this result.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
Related Concept Videos
Longitudinal Research
Mechanical Efficiency of Real Machines
However, in reality, no machine can be truly ideal, and all of them experience some...
Fatigue
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Longitudinal Studies
Interpreting Run Charts