Double lumen endobronchial tube intubation: lessons learned from anatomy
Robert B Cameron1, Warwick J Peacock2, Xinlian Grace Chang2
1Division of Thoracic Surgery, Department of Surgery, David Geffen School of Medicine at UCLA and the Division of Thoracic Surgery, Department of Surgery and Perioperative Care, West Los Angeles VA Medical Center, Los Angeles, CA, USA.
Background:
Double lumen endobronchial tubes (DLTs) are frequently used to employ single lung ventilation strategies during thoracic surgical procedures. Placement of these tubes can be challenging even for experienced clinicians. We hypothesized that airway anatomy, particularly of the glottis and proximal trachea, significantly impacts the ease or difficulty in placement of these tubes.
Methods:
Images from 24 randomly selected Positron Emission Tomography - Computed Tomography (PET-CT) scans were evaluated for several anatomic aspects of the upper airway, including size and angulation of the glottis and proximal tracheal using calibrated CT measurements and an online digital protractor. The anatomic issues identified were confirmed in cadaveric anatomic models.
Results:
Proximal tracheal diameter measurements in PET-CT scans demonstrated a mean ± standard deviation of 20.4 ± 2.5 mm in 12 males and 15.5 ± 0.98 mm in 12 females (p < 0.001), and both were large enough to accommodate 39 French and 37 French DLTs in males and females, respectively. Subsequent measurements of the posterior angulation of the proximal trachea revealed a mean angle of 40.8 ± 5.7 degrees with no sex differences. By combining the 24 individual posterior tracheal angles with the 16 angled distal tip measurements DLTs (mean angle 24.9 ± 2.1 degrees), we created a series of 384 patient intubation angle scenarios. This data clearly showed that DLT rotation to a full 180 degrees decreased the mean intubation angle between the DLT and the proximal trachea from a mean of 66.6 ± 5.9 to only 15.8 ± 5.9 degrees.
Conclusions:
Rotation of DLTs a full 180 instead of the recommended 90 degrees facilitates DLT intubations.
More Related Videos
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Anatomy of Respiratory System II: Lower Respiratory Tract
The Larynx
It is located between the pharynx and the trachea, acts as a passageway for air, and hosts several critical structures, such as the epiglottis, vocal cords, and glottis. The epiglottis acts as a gateway, guiding food to the...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...