Related Experiment Video
Updated: Jun 28, 2025

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
Published on: November 11, 2020
Suboptimal peak inspiratory flow rate: a noticeable risk factor for inhaler concordance in patients with chronic
Weiwei Meng1,2,3,4, Ruoyan Xiong1,2,3,4, Zhiqi Zhao1,2,3,4
1Department of Pulmonary and Critical Care Medicine, The Second Xiangya Hospital of Central South University, Changsha, Hunan, China.
Background:
Inhaler concordance and the peak inspiratory flow rate (PIFR) are important determinants of treatment effects in patients with chronic airway diseases. Adequate PIFR is required for driving aerosol medication into the lower respiratory tract. However, the relationship between them has not been discussed previously. This study aimed to describe the characteristics of inhaler concordance and PIFR in Chinese patients with chronic airway diseases and discuss the associated variables and the relationship between them.
Methods:
In this single-centre, observational study, a total of 680 patients with chronic airway diseases were enrolled from July 2021 to April 2023. We collected data on the socio-demographic and clinical variables of inhaler concordance using the test of adherence to inhalers (TAI) and PIFR. Multivariate logistic regression was conducted to examine variables related to inhaler concordance and PIFR.
Results:
A total of 49.4% of patients had low concordance. Patients with chronic obstructive pulmonary disease (COPD) were more concordant than patients with asthma (mean TAI score: 43.60 vs 41.20; p<0.01), while there was no difference in concordance between the asthma-COPD overlap group and the asthma or COPD group. Suboptimal PIFR (adjusted OR, 1.61; 95% CI 1.04 to 2.51) increased the risk of poor concordance among all patients, while triple therapy (adjusted OR, 0.60; 95% CI 0.35 to 0.86) reduced the risk. A total of 54.9% of patients had suboptimal PIFR. Older age, lower educational level, use of dry powder inhalers and lower forced expiratory volume in 1 s % predicted were significantly correlated with insufficient PIFR. Subgroup analysis revealed a greater proportion of patients with insufficient PIFR during exacerbation than during the stable phase (61.7% vs 43.5%, p<0.001).
Conclusion:
Inhaler concordance was low, and suboptimal PIFR was a risk factor for poor concordance among Chinese patients with chronic airway diseases. In addition, current inhalation devices may not be suitable, and PIFR reassessment should be considered for patients with COPD during exacerbation.
Trial Registration Number:
The study was registered in chictr.org.cn (ChiCTR2100052527) on 31 October 2021.
Related Concept Videos
Inhaled Medications
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Chronic Obstructive Pulmonary Disease-I: Introduction
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation

