The Calf Raise App shows good concurrent validity compared with a linear encoder in measuring total concentric work
Farshad Ashnai1,2, Jakob Lindskog2, Annelie Brorsson1,3
1Department of Orthopaedics, The Institute of Clinical Sciences at Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Purpose:
The linear encoder and the Calf Raise App have been shown to be valid for measurements of plantar flexor muscular endurance in the heel raise test when compared with gold standard equipment. However, the validity of the Calf Raise App has not yet been compared with a linear encoder, an instrument commonly used in clinical and research settings. The purpose of this study was to determine the concurrent validity of the Calf Raise App compared with a linear encoder for the measurement of average heel raise height and total concentric work in the heel raise test.
Methods:
Fifty TeamGym athletes (82% females) from an on-going prospective study were included (mean [SD] age: 20 [7] years; body mass index (BMI) = 21.3 [2.5]). Concurrent validity was analysed with single measures intraclass correlation coefficient (ICC) using a two-way mixed effects, consistency model.
Results:
Ninety-eight samples were included in the analysis. The mean (SD) average heel raise height and total concentric work measured by the linear encoder and Calf Raise App were 9.9 (1.4) and 7.5 (1.2) cm, and 1728 (584) and 1291 (450) J, respectively. The mean (SD) number of unilateral heel raises was 30 (7.5). The results showed poor to moderate concurrent validity for the measurement of average heel raise height (ICC: 0.62; 95% confidence interval [CI]: 0.48-0.73). Good to excellent concurrent validity was shown for the measurement of total concentric work (ICC: 0.89; 95% CI: 0.84-0.93).
Conclusion:
The Calf Raise App shows good concurrent validity in the heel raise test compared with a linear encoder in measuring total concentric work but not average height. While caution is recommended when comparing results from the different instruments, each instrument can be used separately to compare between-limb differences or changes over time in plantar flexor muscular endurance in clinical and research settings.
Level Of Evidence:
Level III.
Related Concept Videos
Isotonic and Isometric Muscle Contractions
Isotonic contractions
Isotonic contractions occur when a muscle changes length while...
Mechanical Efficiency of Real Machines
However, in reality, no machine can be truly ideal, and all of them experience some...
Work Done Over an Inclined Plane
The work done by gravity to move a rigid body, or the work done by an opposing force to move a rigid body against gravity, can be calculated using the center-of-mass framework. It is the line integral of the force of gravity over the path, considered positive if...
Eccentric Loading
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Power Expended by a Constant Force