Ultratrace eNose Sensing of VOCs toward Breath Analysis Applications Utilizing an eNose-Based Analyzer
Johannes Glöckler1, Carsten Jaeschke1, Marta Padilla2
1Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany.
Abstract:
This proof-of-principle study presents the ability of the recently developed iLovEnose to measure ultratrace levels of volatile organic compounds (VOCs) in simulated human breath based on the combination of multiple gas sensors. The iLovEnose was developed by our research team as a test bed for gas sensors that can be hosted in three serially connected compact low-volume and temperature-controlled compartments. Herein, the eNose system was equipped with conventional semiconducting metal oxide (MOX) gas sensors using a variety of base technologies providing 11 different sensor signals that were evaluated to determine six VOCs of interest at eight low to ultralow concentration levels (i.e., ranging from 3 to 0.075 ppm) at humid conditions (90% rh at 22 °C). The measurements were randomized and performed four times over a period of 2 weeks. Partial least-squares regression analysis was applied to estimate the concentration of these six analytes. It was shown that the iLovEnose system is able to discriminate between these VOCs and provide reliable quantitative information relevant for future applications in exhaled breath analysis as a diagnostic disease detection or monitoring device.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
Olfaction
The olfactory receptors are embedded in the cilia of the...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II