Dosimetric comparison of advanced radiation techniques for scalp-sparing in low-grade gliomas
Hang Yu1, Shuangshuang He2, Yisong He3
1Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, 610041, Chengdu, Sichuan Province, China.
Background:
Alopecia causes significant distress for patients and negatively impacts quality of life for low-grade glioma (LGG) patients. We aimed to compare and evaluate variations in dose distribution for scalp-sparing in LGG patients with proton therapy and photon therapy, namely intensity-modulated proton therapy (IMPT), intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and helical tomotherapy (HT).
Methods:
This retrospective study utilized a dataset comprising imaging data from 22 patients with LGG who underwent postoperative radiotherapy. Treatment plans were generated for each patient with scalp-optimized (SO) approaches and scalp-non-optimized (SNO) approaches using proton techniques and photons techniques; all plans adhered to the same dose constraint of delivering a total radiation dose of 54.04 Gy to the target volume. All treatment plans were subsequently analyzed.
Results:
All the plans generated in this study met the dose constraints for the target volume and OARs. The SO plans resulted in reduced maximum scalp dose (Dmax), mean scalp dose (Dmean), and volume of the scalp receiving 30 Gy (V30) and 40 Gy (V40) compared with SNO plans in all radiation techniques. Among all radiation techniques, the IMPT plans exhibited superior performance compared to other plans for dose homogeneity as for SO plans. Also, IMPT showed lower values for Dmean and Dmax than all photon radiation techniques.
Conclusion:
Our study provides evidence that the SO approach is a feasible technique for reducing scalp radiation dose. However, it is imperative to conduct prospective trials to assess the benefits associated with this approach.