Related Experiment Video
Updated: Jun 28, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Failure mechanism and bearing force of CFRP strengthened square hollow section under compressive load
Can Huang1, Yan-Hui Wei1,2, Ke-Jian Ma1,2
1Research Center of Space Structures, Guizhou University, Guiyang, 550025, China.
Abstract:
Carbon fibre-reinforced polymer (CFRP) plates can efficiently repair or enhance the mechanical properties of the square hollow section. However, the loading end of such a CFRP-strengthened member is prone to local bearing failure under compressive load. Given this limitation, an innovative CFRP-plate-strengthened square hollow section composite member (CFRP-SHSCM) was raised, and the thick-walled section was welded on both ends of the thin-walled steel column. The mechanical properties of CFRP-SHSCMs were investigated through parameter finite element (FE) analysis, focusing on the influence of the amount of CFRP layers (nc), the slenderness ratio (λ), the initial geometric imperfections (v0), the CFRP layouts (2S and 4S) and the length of the exposed steel column (Le). The load-displacement curves, the bearing force, and typical failure modes were also acquired. Results indicated that with increasing nc and v0, and decreasing λ, the conventional CFRP-SHSCMs were prone to local bearing failure with poor ductility, leading to the insufficient use of the CFRP plate, in contrast, the improved CFRP-SHSCMs primarily underwent overall buckling failure and exhibited better bearing force and ductility. Finally, the modified Perry-Robertson formula was put forward to predict the ultimate load of the CFRP-SHSCMs. The coefficients of variation between the FE simulation and the theoretical results were 0.00436 and 0.0292, respectively.
Related Concept Videos
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Method of Sections: Problem Solving II
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
Design of Prismatic Beams for Bending
Bearing Stress
Due to the intricacy of these microforces, an average value, known as bearing stress, is often used by...

