Related Experiment Video
Updated: Jul 17, 2026

Implantation of the Syncardia Total Artificial Heart
Published on: July 18, 2014
Pacing Using Cardiac Implantable Electric Device During TAVR: 10-Year Experience of a High-Volume Center
Magda Haum1, Julius Steffen1, Sebastian Sadoni2
1Department of Medicine I, University Hospital Munich, Ludwig Maximilians University, Munich, Germany; German Centre for Cardiovascular Research (DZHK), Munich, Germany.
Background:
Transcatheter aortic valve replacement (TAVR) is an effective and safe therapy for severe aortic stenosis. Rapid or fast pacing is required for implantation, which can be performed via a pre-existing cardiac implantable electric device (CIED). However, safety data on CIEDs for pacing in TAVR are missing.
Objectives:
The aim of this study was to elucidate procedural safety and feasibility of internal pacing with a CIED in TAVR.
Methods:
Patients undergoing TAVR with a CIED were included in this analysis. Baseline characteristics, procedural details, and complications according to Valve Academic Research Consortium 3 (VARC-3) criteria after TAVR were compared between both groups.
Results:
A total of 486 patients were included. Pacing was performed using a CIED in 150 patients and a transient pacemaker in 336 patients. No differences in technical success according to VARC-3 criteria or procedure duration occurred between the groups. The usage of transient pacers for pacing was associated with a significantly higher bleeding rate (bleeding type ≥2 according to VARC-3-criteria; 2.0% vs 13.1%; P < 0.01). Furthermore, impairment of the CIED appeared in 2.3% of patients after TAVR only in the group in which pacing was performed by a transient pacer, leading to surgical revision of the CIED in 1.3% of all patients when transient pacemakers were used.
Conclusions:
Internal pacing using a CIED is safe and feasible without differences of procedural time and technical success and might reduce bleeding rates. Furthermore, pacing using a CIED circumvents the risk of lead dislocation. Our data provide an urgent call for the use of a CIED for pacing during a TAVR procedure in general.