Related Experiment Video
Updated: Jun 28, 2025

Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Ultrasound supports clinical decision-making in determining the Sanders' skeletal maturity score of the hand
Ferdinand Wagner1,2,3, Stefanie König4, Quirin Johannes Wuermeling4
1Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, Ludwig-Maximilians-Universität München, Marchioninistrasse 15, 81377, Munich, Germany. ferdinand.wagner@med.uni-muenchen.de.
Purpose:
The Sanders Scoring System has revolutionized the way we assess the remaining growth potential of the skeleton. However, because it involves radiation exposure, it must be used with caution in children. The purpose of the study was to evaluate whether the Sanders skeletal maturity score (SMS) could be accurately determined using ultrasound (U).
Methods:
We took radiographs (R) of the hand and performed U of the thumb and index finger in 115 patients between six and 19 years of age who were undergoing treatment for scoliosis or limb deformities. Paediatric orthopaedic surgeons, a paediatrician, and a paediatric radiologist were evaluated the blinded images. Those classified images are based on the SMS and the Thumb Ossification Composite Index (TOCI).
Results:
Intrarater reliability was high for SMS and slightly weaker for TOCI, but still significant. Interrater reliability was clear for R and weaker for U in both staging systems. Ultimately, SMS 3 and 7 achieved the highest percentage of concordance (P) of 71.7% and 66.0%, respectively, when U was performed. Combining the clinically relevant groups of SMS 3&4 and SMS 7&8 also significantly increased peak scores (SMS 3 and 4 P = 76.7%; SMS 7 and 8 P = 79.7%). The probabilities of peak scores were significantly weaker when the TOCI score was examined.
Conclusion:
Our study shows that U can be used effectively especially to measure stages 3 and 4 and stages 7 and 8 of SMS. The U method is easy to use and therefore may offer advantages in clinical practice without the need for radiation exposure.