Related Experiment Video
Updated: Jun 28, 2025

A Battery of Motor Tests in a Neonatal Mouse Model of Cerebral Palsy
Published on: November 3, 2016
Nemaline Myopathy in a Hypotonic Neonate: Diagnostic Approach for Early Detection and Management
Annie Vu1, Subah Nanda1, Todd Chassee2
1Medicine, Michigan State University College of Human Medicine, East Lansing, USA.
Abstract:
Neonatal hypotonia presents with low muscle tone and an array of symptoms that vary depending on the etiology. The differential diagnosis for this condition is complex. It is crucial to exclude life-threatening causes before following a diagnostic algorithm and performing additional tests. Given the wide range of clinical symptoms and etiologies for neonatal hypotonia, rapid genetic testing has the potential to expedite diagnosis, reduce invasive testing such as muscle biopsy, reduce hospital stays, and guide condition management. A four-week-old girl was admitted to the emergency department (ED) with a one-day history of lethargy, poor feeding, congestion, cough, and hypoxemia. Given positive rhino-enterovirus testing and high inflammatory markers, antibiotics were administered. Imaging, venous blood gas, and blood cultures were negative, and the patient was admitted to the pediatric intensive care unit (PICU) for hypoxemia. After speech-language pathology (SLP) and occupational therapy (OT) evaluation, weak orofacial muscles and feeding issues resulted in a nasogastric tube placement. A swallow study revealed decreased pharyngeal contraction and post-swallow liquid residue. Laryngoscopy showed mild laryngomalacia and dysphagia with aspiration. Genetic testing identified an ACTA1 mutation and confirmed nemaline myopathy (NM). The patient's oxygen levels dropped further during sleep, resulting in diagnoses of severe obstructive and moderate-severe central sleep apnea. Treatment included oxygen therapy, SLP, physical therapy, albuterol, and cough assists. After discharge, the patient was frequently re-admitted with chronic respiratory failure and bronchiolitis and later had gastrostomy and tracheostomy tubes inserted. This specific case highlights the importance of implementing a diagnostic algorithm for neonatal hypotonia. It is also important for physicians, especially emergency medicine (EM) providers, to first exclude infection, sepsis, and cardiac and respiratory organ failure before looking into other tests. Then, physicians should evaluate for more rare etiologies. In this patient's case, the hypotonia was due to a rare genetic disease, nemaline myopathy, and a multidisciplinary approach was used for this patient's care.
More Related Videos
05:52Early Pathological and Magnetic Resonance Detection of Cerebral Injury Using a Rat Model of Neonatal Hypoxic Ischemic Encephalopathy
Published on: October 28, 2022
08:07Single Myofiber Isolation and Culture from a Murine Model of Emery-Dreifuss Muscular Dystrophy in Early Post-Natal Development
Published on: July 1, 2020