Critical Mineral Separations: Opportunities for Membrane Materials and Processes to Advance Sustainable Economies and

Laurianne Lair1, Jonathan Aubuchon Ouimet1, Molly Dougher1

  • 11Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, Indiana, USA; email: llair@nd.edu, jouimet@nd.edu, mdoughe6@nd.edu, adowling@nd.edu, wphillip@nd.edu.

Related Concept Videos

Overview Of Cell Separation And Isolation01:20

Overview Of Cell Separation And Isolation

Cell separation was first achieved in 1964 by S. H. Seal, who separated large tumor cells from the smaller blood cells using filtration. Two years later, Pohl and Hawk performed experiments on how cells respond differently to a nonuniform electric field based on the cell type. Such observations were the inception of cell separation methods, which allow isolating a single cell type from a heterogeneous sample.
5.6K
Precipitation and Co-precipitation01:17

Precipitation and Co-precipitation

Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
1.8K
Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
393
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
455
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
648