Related Experiment Video
Updated: Jun 27, 2025

Development of an Electrochemical DNA Biosensor to Detect a Foodborne Pathogen
Published on: June 3, 2018
N vacancy and self-enhancement induced high anodic electrochemiluminescence of 3D g-C3N4 for sensitive staphylococcus
Yuxuan Wang1, Xinya Jiang2, Weiwei Cao1
1Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, China.
Abstract:
Here, 3D g-C3N4 with dense N vacancy in its 3D porous interconnected open-framework was synthesized, and the co-reactive 3-(dibutylamino)propylamine (DBAPA) was further covalently coupled onto the surface, resulting in a strong self-enhanced anodic electrochemiluminescence (ECL). Through introduction of high-density N vacancy, for the obtained 3D g-C3N4-NV, the band gap was broadened and the electrical conductivity was enhanced, realizing an obvious ECL improvement. Moreover, after the covalent binding of co-reactive DBAPA, the obtained 3D g-C3N4-NV-DBAPA exhibited a more intensive self-enhanced ECL signal due to the higher co-reaction efficiency originated from shorter electron transfer distance and lower energy loss. Based on the high initial signal of the proposed 3D g-C3N4-NV-DBAPA, a sensitive ECL biosensor with signal "on-off" was fabricated in assistance with multiple horizontal ordered hybridization chain reaction (HO-HCR). Through orderly fixing the reacted DNA chains on the Y-shape DNA structure on the electrode could effectively decrease diffusion process and improve the reaction efficiency of HCR process, resulting in the formation of numerous long horizontal double-strand DNA that could immobilize abundant ferrocene-doxorubicin (Fc-Dox) with ECL quenching effect. Meanwhile, compared to the traditional vertical HCR, the HO-HCR could make the quench reagent closer to the ECL emitter on the electrode surface and obtain a more effective quenching effect to enhance the sensing sensitivity. As a result, the proposed ECL biosensor archived the sensitive measurement of staphylococcus aureus with a detection limit of 10.3 aM.
More Related Videos
06:19Author Spotlight: Advancing SERS Technology: Au@Carbon Dot Nanoprobes for Label-Free Analysis and Imaging
Published on: June 9, 2023
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022