Related Experiment Video
Updated: Jun 27, 2025

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Safety and effectiveness assessment of the surpass evolve (SEASE): a post-market international multicenter study
Juan Vivanco-Suarez1, Mahmoud Dibas1, Demetrius Klee Lopes2
1Department of Neurology, Neurosurgery & Radiology, University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA.
Background:
Flow diverters are the first-line treatment for specific intracranial aneurysms (iA). Surpass Evolve (SE) is a new-generation 64-wire flow diverter with a high braid angle. Current literature on the SE is limited. We aimed to report the first international real-world experience evaluating the safety and effectiveness of the SE.
Methods:
The Safety and Effectiveness Assessment of the Surpass Evolve (SEASE) was a multicenter retrospective international post-marketing cohort study including consecutive patients treated with SE for iAs between 2020 and 2022. Demographic, clinical, and angiographic data were collected. Primary effectiveness was independent core lab adjudicated complete occlusion rates (Raymond-Roy Class 1) at last follow-up. Primary safety were major ischemic/hemorrhagic events and mortality.
Results:
In total, 305 patients with 332 aneurysms underwent SE implantation. The patients had a median age of 59 [50-67] years, and 256 (83.9%) were female. The baseline modified Rankin scale score was 0-2 in 291 patients (96.7%). Most aneurysms were unruptured (285, 93.4%) and saccular (309, 93.1%). Previous treatment was present in 76 (22.9%) patients. The median aneurysm size was 5.1 [3.4-9.0] mm, and the median neck width was 3.6 [2.7-5.1] mm. Most aneurysms were in the internal carotid artery C6 ophthalmic segment (126, 38.0%), followed by the communicating segment (58, 17.5%). At median 10.2 [6.4-12.9] months follow-up, 233 (73.0%) aneurysms achieved complete occlusion. After adjusting for confounders, complete occlusion remained consistent. Major stroke and procedure-related mortality were reported in 6 (2%) and 2 (0.7%) cases, respectively.
Conclusion:
These results demonstrate that SE has a consistently high effectiveness and favorable safety for the treatment of iAs.
More Related Videos
00:04A Clinical Trial Assessing the Safety, Efficacy, and Delivery of Olive-Oil-Based Three-Chamber Bags for Parenteral Nutrition
Published on: September 20, 2019
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Assumptions of Survival Analysis