Related Experiment Video
Updated: Jul 7, 2026

Implementation of In Vitro Drug Resistance Assays: Maximizing the Potential for Uncovering Clinically Relevant Resistance Mechanisms
Published on: December 9, 2015
A framework for the in silico assessment of the robustness of an MPC in a CDC line in function of process variability
Ruben Waeytens1, Daan Van Hauwermeiren2, Wouter Grymonpré3
1Laboratory of Pharmaceutical Process Analytical Technology, Department of Pharmaceutics, Ghent University, Ottergemsesteenweg 460, B-9000 Ghent, Belgium; BIOMATH, Department of Mathematical Modelling, Statistics and Bio-informatics, Ghent University, Coupure Links 653, B-9000 Ghent, Belgium.
Abstract:
The shift from batch manufacturing towards continuous manufacturing for the production of oral solid dosages requires the development and implementation of process models and process control. Previous work focused mainly on developing deterministic models for the investigated system. Furthermore, the in silico tuning and analysis of a control strategy are mostly done based on deterministic models. This deterministic approach could lead to wrong actions in diversion strategies and poor transferability of the controller performance if the system behaves differently than the deterministic model. This work introduces a framework that explicitly includes the process variability which is characteristic of powder handling processes and tests it on a novel continuous feeding-blending unit (i.e., the FE continuous processing system (CPS)), followed by a tablet press (i.e., the FE 55). It employs a stochastic model by allowing the model parameters to have a probability distribution. The performance of a model predictive control (MPC), steering the feed rate of the main excipient feeder to compensate for the feed rate deviations of the active pharmaceutical ingredient (API) feeder to keep the API concentration close to the desired value, is evaluated and the impact of process variability is assessed in a Monte Carlo (MC) analysis. Next to the process variability, a model for the prediction error of the chemometric model and realistic feed rate disturbances were included to increase the transferability of the results to the real system. The obtained results show that process variability is inherently present and that wrong conclusions can be drawn if it is not taken into account in the in silico analysis.
More Related Videos
Related Concept Videos
In vitro Mutagenesis
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This relationship...

