Related Experiment Video
Updated: Jun 27, 2025

Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
Blood pressure and cerebral oxygenation with physiologically-based cord clamping: sub-study of the BabyDUCC trial
Shiraz Badurdeen1,2,3,4, Douglas A Blank5,6,7, Monsurul Hoq8
1Department of Obstetrics, Gynaecology, and Newborn Health, The University of Melbourne, Parkville, VIC, 3052, Australia. shiraz.badurdeen@unimelb.edu.au.
Background:
Cord-clamping strategies may modify blood pressure (BP) and cerebral tissue oxygen saturation (rStO2) immediately after birth.
Methods:
We conducted a sub-study nested within the Baby-Directed Umbilical Cord-Clamping trial. Infants ≥32+0 weeks' gestation assessed as requiring resuscitation were randomly allocated to either physiologically-based cord clamping (PBCC), where resuscitation commenced prior to umbilical cord clamping, or standard care where cord clamping occurred early (ECC). In this single-site sub-study, we obtained additional measurements of pre-ductal BP and rStO2. In a separate observational arm, non-randomised vigorous infants received 2 min of deferred cord clamping (DCC) and contributed data for reference percentiles.
Results:
Among 161 included infants, n = 55 were randomly allocated to PBCC (n = 30) or ECC (n = 25). The mean (SD) BP at 3-4 min after birth (primary outcome) in the PBCC group was 64 (10) mmHg compared to 62 (10) mmHg in the ECC group, mean difference 2 mmHg (95% confidence interval -3-8 mmHg, p = 0.42). BP and rStO2 were similar across both randomised arms and the observational arm (n = 106).
Conclusion:
We found no difference in BP or rStO2 with the different cord clamping strategies. We report reference ranges for BP and rStO2 for late-preterm and full-term infants receiving DCC.
Impact:
Among late-preterm and full-term infants receiving varying levels of resuscitation, blood pressure (BP, at 3-4 minutes and 6 min) and cerebral tissue oxygen saturation (rStO2) are not influenced by timing of cord clamping in relation to establishment of ventilation. Infants in this study did not require advanced resuscitation, where cord clamping strategies may yet influence BP and rStO2. The reference ranges for BP and rStO2 represent the first, to our knowledge, for vigorous late-preterm and full-term infants receiving deferred cord clamping. rStO2 > 90% (~90th percentile) may be used to define cerebral hyperoxia, for instance when studying oxygen supplementation after birth.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure