Assessment of Nocturnal Blood Pressure: Importance of Determining the Time in Bed-A Pilot Study
Niklas Pilz1,2, Viktor Heinz2, Gianfranco Parati3,4
1Institute of Translational Physiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 10117 Berlin, Germany.
Abstract:
Objectives: Nocturnal blood pressure (BP) monitoring is essential for evaluating cardiovascular risk and guiding treatment decisions. However, the standardized narrow-fixed nighttime period between 10 p.m. and 6 a.m. may not accurately reflect individual sleep schedules. This pilot study aimed to investigate the comparability between the standardized nighttime period and actual time in bed (TIB) regarding BP assessment. Further, our goal was to evaluate the clinical relevance of the observed BP differences. Methods: A total of 30 participants underwent 24 h ambulatory blood pressure monitoring (ABPM). Patient-specific TIB was precisely assessed through an accelerometer and a position sensor from the SOMNOtouch NIBP™ (SOMNOmedics GmbH, Randersacker, Germany). We analysed the effect of considering individual TIB as nighttime instead of the conventional narrow-fixed interval on the resulting nocturnal BP levels and dipping patterns. Results: We observed differences in both systolic and diastolic BP between the standardized nighttime period and the TIB. Furthermore, a notable percentage of patients (27%) changed their dipping pattern classification as a function of the nighttime definition adopted. We found strong correlations between the start (r = 0.75, p < 0.01), as well as the duration (r = -0.42, p = 0.02) of TIB and the changes in dipping pattern classification. Conclusions: Definition of nocturnal period based on the individual TIB leads to clinically relevant changes of nocturnal BP and dipping pattern classifications. TIB is easily detected using a body position sensor and accelerometer. This approach may thus improve the accuracy of cardiovascular risk evaluation and enhance treatment strategies.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: