Related Experiment Video
Updated: Jun 27, 2025
![Dynamic Imaging of Chimeric Antigen Receptor T Cells with [18F]Tetrafluoroborate Positron Emission Tomography/Computed Tomography](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F62334.jpg&w=3840&q=50)
Dynamic Imaging of Chimeric Antigen Receptor T Cells with [18F]Tetrafluoroborate Positron Emission Tomography/Computed Tomography
Published on: February 17, 2022
Evaluation of Approaches for the Assessment of HER2 Expression in Breast Cancer by Radionuclide Imaging Using the
Olga Bragina1,2, Liubov Tashireva2,3,4, Dmitriy Loos4
1Department of Nuclear Therapy and Diagnostics, Cancer Research Institute, Tomsk National Research Medical Center, Russian Academy of Sciences, Tomsk 634014, Russia.
Abstract:
Due to its small size and high affinity binding, the engineered scaffold protein ADAPT6 is a promising targeting probe for radionuclide imaging of human epidermal growth factor receptor type 2 (HER2). In a Phase I clinical trial, [99mTc]Tc-ADAPT6 demonstrated safety, tolerability and capacity to visualize HER2 expression in primary breast cancer. In this study, we aimed to select the optimal parameters for distinguishing between breast cancers with high and low expression of HER2 using [99mTc]Tc-ADAPT6 in a planned Phase II study. HER2 expression was evaluated in primary tumours and metastatic axillary lymph nodes (mALNs). SPECT/CT imaging of twenty treatment-naive breast cancer patients was performed 2 h after injection of [99mTc]Tc-ADAPT6. The imaging data were compared with the data concerning HER2 expression obtained by immunohistochemical evaluation of samples obtained by core biopsy. Maximum Standard Uptake Values (SUVmax) afforded the best performance for both primary tumours and mALNs (areas under the receiver operating characteristic curve (ROC AUC) of 1.0 and 0.97, respectively). Lesion-to-spleen ratios provided somewhat lower performance. However, the ROC AUCs were still over 0.90 for both primary tumours and mALNs. Thus, lesion-to-spleen ratios should be further evaluated to find if these could be applied to imaging using stand-alone SPECT cameras that do not permit SUV calculations.
More Related Videos
11:34Building Up a High-throughput Screening Platform to Assess the Heterogeneity of HER2 Gene Amplification in Breast Cancers
Published on: December 5, 2017
10:47Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging
Published on: February 3, 2015