Low-Cost Approach to an Instream Water Depth Sensor Construction Using Differential Pressure Sensors and Arduino
Reagan H Pearce1, Michael A Chadwick2, Bruce Main3
1Department of Geography, Faculty of Social and Historical Sciences, University College London, Gower Street, London WC1E 6BT, UK.
Abstract:
Accurate hydrological data with high spatial resolution is important for flood risk and water resource management, particularly under the context of climate change. The cost of monitoring networks, as well as the characteristics of the hydrological environment itself, can be a barrier to meeting these data requirements, however. This study covers the design and testing of a low-cost, "build-it-yourself", instream water depth sensor providing an assessment of its potential in future hydrological monitoring projects. The low-cost sensor was built using an Arduino microcontroller, a differential pressure sensor and a thermistor, a real-time clock, and an SD card module. The low-cost logger was deployed in tandem with a factory-calibrated Solinst®LevelLogger® 5 Junior for 6 months in the River Wissey, UK. We found the mean absolute error of the Arduino-based logger relative to the commercial setup to be ±0.69 cm for water depth and ±0.415 °C for water temperature. Economically, the Arduino-based logger offers an advantage, costing a total of £133.35 (USD 168.26 at time of publication) comparative to the industrial comparison's cost of £408 (USD 514.83 at time of publication). This study concludes that the low cost of the Arduino-based logger gives a strong advantage to its incorporation in hydrological data collection, if the trade-offs (i.e., time investment and accuracy) are considered acceptable and appropriate for a project.
Related Concept Videos
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...