Coordinate Mapping of Hyolaryngeal Mechanics in Swallowing
Published on: May 6, 2014
Four-dimensional impedance manometry volume metrics for predicting abnormal bolus retention
Panyavee Pitisuttithum1,2, Eric Goudie2,3, Isis K Araujo4
1Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand.
Four-dimensional impedance manometry (4D HRM) offers objective esophageal bolus volume and clearance measurements. The clearance ratio shows strong correlation with timed barium esophagram, potentially replacing it for retention assessment.
Area of Science:
- Gastroenterology
- Esophageal Physiology
- Diagnostic Imaging
Background:
- High-resolution manometry (HRM) requires objective metrics for esophageal bolus volume and clearance.
- Current Chicago classification may be enhanced by novel objective measurements.
- Four-dimensional impedance manometry (4D HRM) offers potential for improved esophageal motility assessment.
Purpose of the Study:
- To compare novel 4D HRM volume metrics with timed barium esophagram (TBE).
- To evaluate the utility of 4D HRM in objectively measuring esophageal bolus transport.
- To determine if 4D HRM metrics can classify esophageal motility abnormalities.
Main Methods:
- Adult patients with esophageal symptoms undergoing HRM and TBE were enrolled.
- A custom program analyzed 4D HRM impedance data to derive esophageal bolus volume and clearance.
- Key 4D HRM metrics included residual volume, maximal volume, retention volume, and clearance ratio.
Main Results:
- The clearance ratio demonstrated the highest accuracy (AUROC 0.89) in predicting abnormal TBE at 5 minutes.
- A strong negative correlation (r = -0.65) was observed between the clearance ratio and TBE retention at 5 minutes.
- 95 patients were analyzed, with varying esophageal motility diagnoses and TBE outcomes.
Conclusions:
- Novel 4D HRM volume metrics provide objective esophageal bolus volume and clearance data.
- The clearance ratio strongly correlates with TBE, suggesting it as a potential TBE substitute.
- 4D HRM offers a promising non-invasive method for assessing esophageal bolus retention.
More Related Videos
08:32Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models
Published on: March 1, 2015
07:41Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Urodynamic Studies: Uroflowmetry