Flow-modulation comprehensive two-dimensional enantio-gas chromatography: A valid and flexible alternative to
Micaela Galletta1, Mariosimone Zoccali2, Cristina Malegori3
1Messina Institute of Technology c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, Former Veterinary School, University of Messina, Viale G. Palatucci snc, 98168, Messina, Italy.
Abstract:
The present research is focused on the proposal of use of flow-modulation comprehensive two-dimensional enantio-gas chromatography (FM eGC × GC) as a valid, flexible, and possibly superior alternative to heart-cutting multidimensional enantio-GC (eMDGC). The latter, a technique of demonstrated utility, is used specifically for the targeted separation of chiral compounds, whereas FM eGC × GC can produce both targeted and high-resolution untargeted information in a single run. It is clearly possible to use eMDGC for untargeted analysis, often with a flame ionization detector (stand-by analysis), to monitor a first-dimension (1D) separation, of much lower peak capacity compared to FM eGC × GC. If eMDGC is used with mass spectrometry (MS), it is normally exploited to monitor the second-dimension (2D) separation. The analytical instrument consisted of automated solid-phase microextraction (SPME), and a low duty-cycle FM eGC × GC system (with time-of-flight MS), equipped with an enantioselective 1D column (2,3-di-O-methyl-6-t-butyl silyl β-cyclodextrin derivative) and a 2D polyethylene glycol one. Ten Marsala wines were subjected to analysis, for the determination of chiral lactones (many at the low ppb level, due to the high concentration capacity of SPME) and for general analyte profiling. In many instances, highly complex chromatograms were attained, with statistical analysis (ANOVA-simultaneous component analysis and partial least squares discriminant analysis) used for sample differentiation.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:50Author Spotlight: Integrating 2D-HPLC-MS and Molecular Networking in Natural Medicine Analysis
Published on: December 8, 2023
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...