Related Experiment Video
Updated: Jun 27, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Stepping Up Recovery: Integrating Patient-reported Outcome Measures and Wearable Technology for Rehabilitation
Ignacio Pasqualini1, Nickelas Huffman1, Alison Klika1
1Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio.
Abstract:
Improvement after knee arthroplasty (KA) is often measured using patient-reported outcome measures (PROMs). However, PROMs are limited due to their subjectivity. Therefore, wearable technology is becoming commonly utilized to objectively assess physical activity and function. We assessed the correlation between PROMs and step/stair flight counts in total (TKA) and partial knee arthroplasty (PKA) patients.Analysis of a multicenter, prospective, longitudinal cohort study investigating the collection of average daily step and stair flight counts, was performed. Subjects (N = 1,844 TKA patients and N = 489 PKA patients) completed the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) and provided numerical rating scale pain scores pre- and postoperatively. Only patients who reported living in a multilevel home environment (N = 896 TKA patients and N = 258 PKA patients) were included in analysis of stair flight counts. Pearson correlation coefficients were calculated to determine correlations between variables.Among TKA patients, pain scores demonstrated a negative correlation to mean step counts at preoperative (r = -0.14, p < 0.0001) and 1-month follow-up (r = -0.14, p < 0.0001). Similar negative correlations were true for pain and stair flight counts at preoperative (r = -0.16, p < 0.0001) and 1-month follow-up (r = -0.11, p = 0.006). KOOS JR scores demonstrated weak positive correlations with mean step counts at preoperative (r = 0.19, p < 0.0001) and 1-month postoperative (r = 0.17, p < 0.0001). Similar positive correlations were true for KOOS JR scores and stair flight counts preoperatively (r = 0.13, p = 0.0002) and at 1-month postoperatively (r = 0.10, p = 0.0048). For PKA patients, correlations between pain and KOOS JR with step/stair counts demonstrated similar directionality.Given the correlation between wearable-generated data and PROMs, wearable technology may be beneficial in evaluating patient outcomes following KA. By combining subjective feedback with the objective data, health care providers can gain a holistic view of patients' progress and tailor treatment plans accordingly.
More Related Videos
09:42Using Continuous Data Tracking Technology to Study Exercise Adherence in Pulmonary Rehabilitation
Published on: November 8, 2013
05:54A Rehabilitation Program of Exoskeleton-assisted Body Weight-Supported Treadmill Training with Non-immersive Virtual Reality for Stroke Patients
Published on: May 16, 2025