Potential risk assessment: a model for quality evaluation in fluoroscopy-guided interventional procedures
Marcus Oliveira1,2, Marcus Navarro1,2, Eliana Costa3
1Department of Health Technology and Biology, Federal Institute of Bahia, Salvador, 40301-015, Brazil.
A new model for potential risk assessment in interventional radiology was developed and applied across 121 institutions over 8 years. This model aids in monitoring patient and occupational radiation doses for improved safety during fluoroscopy procedures.
Area of Science:
- Medical Imaging
- Radiology
- Radiation Safety
Background:
- Interventional radiology procedures involve significant radiation exposure.
- Effective risk assessment and safety monitoring are crucial in these settings.
- Existing models may not comprehensively address both patient and occupational doses.
Purpose of the Study:
- To introduce and evaluate a novel model for potential risk assessment (MARP) in interventional radiology.
- To establish a system for monitoring patient and occupational radiation doses.
- To enhance safety protocols in fluoroscopy procedures.
Main Methods:
- Development of the Model for Potential Risk Assessment (MARP) with a 0-5 indicator scale.
- Categorization of radiation levels by gender, procedure type, Kerma air product (Pka), and accumulated dose (mGy).
- Application of the MARP model across 121 institutions over 8 years, collecting data on 201,656 patient doses and 8,007 occupational doses.
Main Results:
- The MARP model was successfully implemented in numerous institutions, gathering extensive radiation dose data.
- Detailed records of both patient (average 22,406/year) and occupational (average 890/year) radiation doses were collected.
- The study demonstrated a viable strategy for quality evaluation in fluoroscopy.
Conclusions:
- The MARP model provides a robust framework for potential risk assessment in interventional radiology.
- Implementation of a compulsory information system is effective for monitoring radiation safety.
- This approach contributes to improved quality evaluation and safety in fluoroscopic procedures.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
11:27Magnetically-Assisted Remote Controlled Microcatheter Tip Deflection under Magnetic Resonance Imaging
Published on: April 4, 2013
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...