Related Experiment Video
Updated: Aug 4, 2026

Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
Published on: January 3, 2011
Analysis of Corneal Biomechanical Properties in Different Keratotopographic Patterns of Keratoconus
Elena Gennadievna Solodkova1, Boris Eduardovich Malyugin2, Igor Nikolayevich Zakharov3
1Volgograd Branch of S. Fyodorov Eye Microsurgery Federal State Institution, Volgograd, Russia.
Purpose:
To analyze the frequency of main keratotopographic patterns at the 1st, 2nd, and 3rd stages of keratoconus and investigate corneal biomechanical properties across different patterns.
Methods:
The study comprised two stages. The first stage was computational-experimental, where we utilized COMSOL Multiphysics® software (COMSOL AB, Stockholm, Sweden) to mathematically model corneal mechanical behavior under intraocular pressure and pulsed air jet action in both normal and keratoconic conditions. The second stage was the clinical phase, during which we retrospectively analyzed the examination results of both healthy subjects and patients with keratoconus. In total, the study included 256 eyes (256 subjects). Among them, 174 eyes (174 healthy individuals) had normal corneas with different refractions, and 82 eyes (82 individuals) had stages 1, 2, and 3 of keratoconus based on Amsler-Krumeich classification. The keratotopographic characteristics of the participants were assessed using Sirius (Schwind, Germany) and Pentacam AXL (OCULUS Optikgeräte GmbH, Germany) keratotomographs, while the corneal biomechanical properties were studied using noncontact tonometry with the Corvis ST device (OCULUS Optikgeräte GmbH, Germany). The study focused on evaluating corneal stiffness index values in the central optical zone under various keratotopographic patterns. In addition, it compared the elastic coefficient values c1, c2, and c3 for the model of hyperelastic behavior of corneal material outside the keratoconus zone. Furthermore, the study examined the values of reduced stiffness zone characteristics, including the stiffness reduction factor ψmax, effective radius Rk, and the ratio of maximum and minimum strain intensity in keratoconus of different stages.
Results:
The mean age of the patients in the study was 30.16 ± 8.31 years, with 166 men and 90 women participating. The study revealed typical keratotopographic patterns in the examined keratoconus stages, as well as their occurrence frequency. In the 1st stage of keratoconus, the pattern of asymmetric astigmatism was noted more frequently (in 75% of cases). In the 2nd stage, the pattern with an ectasia zone in the lower cornea was observed in 80% of cases, and in the 3rd stage, a centrally located keratotopographic ectasia pattern was found in 42% of cases. Comparative analysis showed that the greatest decrease in stiffness parameter (SpA1) and stress-strain index occurred in the central pattern (by 64% and 46%, respectively), while the least decrease was observed in local corneal radius reduction in the lower cornea (by 42% and 33%, respectively).
Conclusions:
The decrease in strength properties in keratoconus occurs in a local area, the size and degree of which are determined by the disease stage. The indicated biomechanical parameters are consistent regardless of the shape and localization of keratotopographic patterns but are relevant to diagnostic specifications using the Corvis ST pneumotonometer, which assesses corneal properties in the apical zone.
More Related Videos
07:29Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
07:51Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
Related Concept Videos
Membrane Fluidity
Mosaic nature of the membrane
The mosaic characteristic of the membrane helps the plasma membrane remain fluid. The integral proteins and lipids exist as separate but loosely-attached molecules in the membrane. The membrane is a relatively...
Mechanisms of Membrane-bending
Membrane bending can happen due to intrinsic changes in lipid composition or extrinsic association with different proteins. The proteins involved...
Conformations of Cyclohexane
The chair form is the most stable and derives its name from its resemblance to the “easy chair.” In the chair conformation, two carbon atoms are arranged out-of-plane — one above and one below, minimizing the torsional strain. In the chair form, the bond angle is very close to the ideal tetrahedral value,...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive force...
Unsymmetric Bending - Angle of Neutral Axis
When a bending moment is applied at an angle θ concerning the vertical axis of a symmetrical member, it can be resolved into components along the member's principal centroidal axes. The...
Shape and Texture of Coarse Aggregate