Related Experiment Video
Updated: May 12, 2026

Inactivation of Pathogens via Visible-Light Photolysis of Riboflavin-5′-Phosphate
Published on: April 6, 2022
Ultraviolet light C prototype device against Sporothrix brasiliensis as a potential physical method for surface
Anderson Luis Terçola1, Vanice Rodrigues Poester1,2, Lívia Silveira Munhoz1,2
1Laboratório de Micologia, Faculdade de Medicina (FAMED), Universidade Federal Do Rio Grande (FURG), Campus Saúde. Visconde de Paranaguá 102, Centro, Rio Grande, Rio Grande do Sul (RS), 96201-900, Brazil.
Abstract:
Sporothrix brasiliensis is recognized as an emergent fungal pathogen and the high amount of fungal propagules in the lesions of infected cats allows the contamination of surfaces by direct contact. Given that the environment can play a role in the transmission of this fungus, effective methods to eliminate this pathogen from contaminated surfaces are necessary. Physical methods, such as ultraviolet light C (UVC), are broad used for surfaces disinfection, however, non-data about its activity against S. brasiliensis is reported. Therefore, we aimed to evaluate an easy handled prototype of a UVC device, in the inhibition of S. brasiliensis. Three doses and times of exposure of irradiance were tested: 3.5 mJ/cm2 (1 s), 5.25 mJ/cm2 (1.5 s) and 329 mJ/cm2 (94 s) against a standardized inoculum of yeast and mold phase of S. brasiliensis. A decrease in CFU was shown in all doses of irradiance in both phases of S. brasiliensis, the average reduction ranged from 78 to 100% among doses, being a complete fungicidal activity achieved against the yeast phase after the 94 s exposure (329 mJ/cm2). Our data shows that UVC is a potential physical method for disinfection of surfaces contaminated with S. brasiliensis, and the prototype device developed provides an easy handling, and quickly results.
More Related Videos
Related Concept Videos
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration

