Correlation of oxygenation indices in invasive mechanical ventilated adult patients
Ravi Jain1, Ashish Jain1, Srishti Jain1
1Department of Critical Care Medicine, Mahatma Gandhi Medical College and Hospital, Jaipur, Rajasthan, India.
Background:
Mechanical ventilation is essential for managing acute respiratory failure, but traditional methods of assessing oxygenation, like the PaO2/FiO2 ratio, pose challenges due to invasiveness and cost.
Objective:
This single-centre prospective observational study aimed to assess the potential of the non-invasive Oxygen Saturation Index (OSI), utilising SpO2 measurements, to diagnose hypoxemia in mechanically ventilated adults. The study sought to establish correlations between OSI, oxygenation index (OI), PaO2/FiO2 ratio and SpO2/FiO2 ratio.
Methods:
From August 2022 to July 2023, data was collected from 1055 mechanically ventilated intensive care unit patients. Statistical analysis included correlation tests, receiver operating curve (ROC) analysis and cut-off value determination for hypoxemia diagnosis.
Results:
We found that the P/F ratio had a statistically significant negative correlation with OI (correlation coefficient -0.832, P value: 0.000 in hypoxemic group and correlation coefficient -0.888, P value: 0.000 in the non-hypoxemic group), and OSI (correlation coefficient -0.746, P value: 0.000 in hypoxemic group and correlation coefficient -0.629, P value: 0.000 in non-hypoxemic group) and has a positive correlation with P/F ratio (correlation coefficient 0.92, P value: 0.000 in hypoxemic group and correlation coefficient -0.67, P value: 0.000 in non-hypoxemic group). OI and OSI had a statistically significant correlation (correlation coefficient 0.955, P value: 0.000 in hypoxemic group and correlation coefficient 0.815, P value: 0.000 in non-hypoxemic group). on ROC analysis P/F ratio was the most accurate in predicting hypoxia followed by OI and OSI. with a cut-off value, of OI being 7.07, and that for OSI being 3.90, at an 80% sensitivity level to diagnose hypoxemia.
Conclusion:
OSI can serve as a dependable surrogate for OI, simplifying ARDS severity assessment. The P/F ratio is the most accurate predictor of hypoxia. Further research, especially in larger multicentre studies, is needed to validate these findings and explore the long-term clinical implications of using OSI for oxygenation monitoring in mechanically ventilated patients.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
12:29Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...