Left bundle branch pacing set to outshine biventricular pacing for cardiac resynchronization therapy?

Akash Batta1, Juniali Hatwal2

  • 1Department of Cardiology, Dayanand Medical College and Hospital, Ludhiana 141001, India. akashbatta02@gmail.com.

PubMed

Related Concept Videos

Electrophysiology of Normal Cardiac Rhythm01:19

Electrophysiology of Normal Cardiac Rhythm

The normal cardiac rhythm is a synchronized electrical activity that facilitates the regular and coordinated contraction of the heart muscle. This process is essential for efficient blood circulation throughout the body. The fundamental elements involved in establishing and maintaining this rhythm include the unique electrical properties of cardiac muscle cells, the sinoatrial (SA) node's pacemaker function, the specialized conducting system, and the ionic mechanisms underlying each phase...
3.8K
Heart Failure Drugs: Inotropic Agents01:26

Heart Failure Drugs: Inotropic Agents

Positive inotropic agents are commonly used as the first line of treatment for heart failure. One such agent is digoxin, derived from the genus Digitalis, which has been known for centuries but effectively utilized since 1785. However, these cardiac glycosides can have potentially toxic effects due to their mechanism of action, which involves inhibiting Na+/K+-ATPase and increasing contractility. Digoxin is absorbed orally and distributed in various tissues, including the CNS. It has a long...
574
Cardiac Action Potential01:30

Cardiac Action Potential

Cardiac action potentials are essential for proper heart function, enabling the rhythmic contractions needed for adequate blood circulation. Nodal cells and Purkinje fibers, specialized for electrical conduction, generate these action potentials.
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
1.4K
Imbalances in Cardiac Output01:26

Imbalances in Cardiac Output

The heart's primary function is to pump blood throughout the body, maintaining a balance between blood sent out (cardiac output) and blood returning (venous return). If this balance is disrupted, it can result in congestive heart failure (CHF), a severe condition where the heart becomes an inefficient pump, leading to inadequate blood circulation.
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
1.4K
The Cardiac Cycle01:13

The Cardiac Cycle

The heart beats rhythmically in a sequence called the cardiac cycle—a rapid coordination of contraction (systole) and relaxation (diastole).
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
87.8K
Conduction System of the Heart01:19

Conduction System of the Heart

Autorhythmicity is a term that refers to the heart's inherent ability to generate electrical signals and instigate muscle contractions. This self-regulating conduction system within the heart consists of two key components: the pacemaker cells and specialized conducting cells.
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
6.3K