Related Experiment Video
Updated: May 7, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Radiographic study of direct anterior approach hip arthroplasty: a 10-15 year follow-up of Chinese patients
Weilin Sang1, Peng Lai1, Xun Xu1
1Department of Orthopaedics, Shanghai General Hospital, Shanghai, 201620, China.
Background:
Controversy remains over whether different surgical approaches exert an impact on the component positioning in total hip arthroplasty. We conducted a retrospective study to reveal the long-term position of prostheses in the first group of patients in China who underwent direct anterior hip arthroplasty.
Methods:
Collected were data from 350 patients who underwent direct anterior hip arthroplasty between 2008 and 2013, including demographic information, imaging data, Harris hip scores, and surgical complications. Variables, measured radiographically or by CT, included hip offset, leg length discrepancy, component position, and stability within one week after surgery and at the last follow-up. The data were subjected to statistical analysis by using paired t-tests and Pearson chi-square tests.
Results:
Data were harvested by follow-up and self-reported questionnaires. The postoperative follow-up lasted for 13.1 years on average (minimum, 10 years; maximum, 15 years), and the overall survival rate of hip prostheses was 96.3%. The mean Harris score at the final follow-up was 91.8 points. After excluding patients with significant preoperative hip deformities, the incidence of postoperative limb inequality (> 5 mm) was 4.9% at the last follow-up, and the incidence of hip offset discrepancy (> 5 mm) was 14.6%. The overall proportion of the acetabular components located in the Lewinnek safe zone was 77.7%, whereas the proportion of femoral prostheses in the safe zone (< 3° inclination) was 94.0%. Based on the revised data and the last follow-up imaging, the total proportion of acetabular and femoral prostheses with a radiolucence of > 2 mm was 5.1%.
Conclusion:
Direct anterior approach hip arthroplasty could achieve excellent component positioning and long-term prosthesis survival in patients without severe hip deformities.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
08:40Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
Published on: April 19, 2024