Added value of 40 keV virtual monoenergetic images for diagnosing malignant pleural effusion on chest CT
Nahyeon Kim1,2, Kyungsoo Bae1,2, Ho Cheol Kim3
1Department of Radiology, Gyeongsang National University Changwon Hospital, 555 Samjeongja-dong, Seongsan-gu, Changwon, Republic of Korea.
Objective:
This study aimed to evaluate the added value of 40 keV virtual mono-energetic images (VMIs) obtained from dual-layer detector CT (DLCT) for diagnosing malignant pleural effusion (MPE) in patients presenting with unilateral pleural effusion on chest CT.
Materials And Methods:
This retrospective study included 75 patients with unilateral pleural effusion who underwent contrast-enhanced chest CT scans using DLCT. Quantitative and qualitative assessments of the visibility of pleural thickening were conducted on both conventional 120 kVp images and 40 keV VMIs. Two independent radiologists reviewed chest CT scans with or without 40 keV VMIs to detect pleural nodules or nodular thickening for the diagnosis of MPE. Diagnostic performances were compared and independent predictors of MPE were identified through multivariate logistic regression analysis using CT and clinicopathologic findings.
Results:
Pleural thickening associated with MPE demonstrated a higher contrast-to-noise ratio value and greater visual conspicuity in 40 keV VMIs compared to benign effusions (p < 0.05). For both readers, the use of 40 keV VMIs significantly improved (p < 0.05) the diagnostic performance in terms of sensitivity and area under the curve (AUC) for diagnosing MPE through the detection of pleural nodularity. Inter-observer agreements between the two readers were substantial for both 120 kVp images alone and the combined use of 40 keV VMIs. Initial cytology results and pleural nodularity at 40 keV were identified as independent predictors of MPE.
Conclusion:
The use of 40 keV VMIs from DLCT can improve diagnostic performance of readers in detecting MPE among patients with unilateral pleural effusion.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
X-ray Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...