Related Experiment Video
Updated: Jun 21, 2026

Substernal Thyroid Biopsy Using Endobronchial Ultrasound-guided Transbronchial Needle Aspiration
Published on: November 10, 2014
TransEBUS: The interpretation of endobronchial ultrasound image using hybrid transformer for differentiating
Ching-Kai Lin1, Shao-Hua Wu2, Yi-Wei Chua2
1Department of Medicine, National Taiwan University Cancer Center, Taipei, Taiwan; Department of Internal Medicine, National Taiwan University Hospital Hsin-Chu Branch, Hsin-Chu, Taiwan; Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan; Department of Department of Mechanical Engineering, College of Engineering, National Yang Ming Chiao Tung University, Hsin-Chu, Taiwan.
Abstract:
The purpose of this study is to establish a deep learning automatic assistance diagnosis system for benign and malignant classification of mediastinal lesions in endobronchial ultrasound (EBUS) images. EBUS images are in the form of video and contain multiple imaging modes. Different imaging modes and different frames can reflect the different characteristics of lesions. Compared with previous studies, the proposed model can efficiently extract and integrate the spatiotemporal relationships between different modes and does not require manual selection of representative frames. In recent years, Vision Transformer has received much attention in the field of computer vision. Combined with convolutional neural networks, hybrid transformers can also perform well on small datasets. This study designed a novel deep learning architecture based on hybrid transformer called TransEBUS. By adding learnable parameters in the temporal dimension, TransEBUS was able to extract spatiotemporal features from insufficient data. In addition, we designed a two-stream module to integrate information from three different imaging modes of EBUS. Furthermore, we applied contrastive learning when training TransEBUS, enabling it to learn discriminative representation of benign and malignant mediastinal lesions. The results show that TransEBUS achieved a diagnostic accuracy of 82% and an area under the curve of 0.8812 in the test dataset, outperforming other methods. It also shows that several models can improve performance by incorporating two-stream module. Our proposed system has shown its potential to help physicians distinguishing benign and malignant mediastinal lesions, thereby ensuring the accuracy of EBUS examination.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Mitral Stenosis II: Clinical features and Diagnostic Tests