Related Experiment Video
Updated: Jun 27, 2025

Mechano-Node-Pore Sensing: A Rapid, Label-Free Platform for Multi-Parameter Single-Cell Viscoelastic Measurements
Published on: December 2, 2022
Graph Laplace Regularization-based pressure sensor placement strategy for leak localization in the water distribution
Menglong Cheng1, Juan Li1, Chunyue Wang1
1College of Communication Engineering, Jilin University, Changchun, China.
Abstract:
Urban water distribution networks (WDNs) have wide range and intricate topology, which include leakage, pipe burst and other abnormal states during production and operation. With the continuous development of the Internet of Things (IoT) technology in recent years, the means of monitoring the WDNs by using wireless sensor network technology has gradually received attention and extensive research. Most of the existing researches select the deployment location of sensors according to the hydraulic state of the WDNs, but the connectivity and topology between the nodes of the WDNs are not fully considered and analyzed. In this study, a new method that can integrate the topological features and hydraulic model information of the WDN is proposed to solve the problem of optimal sensor placement. First, the method preprocesses the covariance matrix of the pressure sensitivity matrix of the water distribution network by a diffusion kernel-based data prefiltering method and obtains the new network topology weights and its Laplacian matrix under the constraints of the network topology through a data-based graphical Laplacian learning method. Then, the sensor placement problem is transformed into a matrix minimum eigenvalue constraint problem by the Graph Laplace Regularization (GLR)-based method, and finally the selection of sensor nodes is accomplished by the method based on Gershgorin Disc Alignment (GDA). The proposed strategy is tested on a passive Hanoi network, an active Net 3 network, and a larger network, PA2, and is compared with some existing methods. The results show that the proposed solution achieves good performance in three different leak localization methods.
More Related Videos
Related Concept Videos
Design Example: Designing a Residential Plumbing System
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific...
Plane Potential Flows
Uniform...
Fluid Pressure over Flat Plate of Constant Width
The resultant force...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...

