Doppler-derived pulmonary pulse transit time measurements in chronic obstructive pulmonary disease: Reproducibility
Friederike Löffler1, Mechthild Westhoff-Bleck1, Tobias Welte2,3
1Department of Cardiology and Angiology, Hannover Medical School, Hannover, Germany.
Introduction:
Doppler-derived pulmonary pulse transit time (pPTT) is an auspicious hemodynamic marker in chronic pulmonary diseases. The aim is to compare four distinct pPTT measurements and its relation to right cardiac and pulmonary function.
Methods:
Prospectively, 25 chronic obstructive pulmonary disease (COPD) patients (four patients excluded) and 32 healthy subjects underwent repeated distinct pPTT measurements, standard echocardiography, and pulmonary function testing on the same day. pPTT was defined as the interval from the R or Q-wave in the electrocardiogram to the corresponding pulse wave Doppler peak late systolic (S) 2 or diastolic (D) pulmonary vein flow velocity (pPTT R-S, Q-S, R-D, Q-D). Reproducibility was assessed using Bland-Altman analysis, coefficient of variation (COV), intraclass correlation coefficient (ICC), and power calculations. Associations with right ventricular RV tissue and pulse wave Doppler velocities (RV E', RV S', RV A', RV E, RV A, RV E/E', RV E/A), TAPSE, right ventricular fractional area change, left ventricular systolic and diastolic function (LV ejection fraction, E, A, E/A, E/E', septal E', lateral E'), LA diameters, as well as forced expiratory volume in 1 s, forced vital capacity (FVC) predicted (%), and in liters were analyzed.
Results:
There was no significant difference and no bias between pPTT measures (p range: .1-.9). COV was in COPD 1.2%-2.3%, in healthy subjects 1.0%-3.1%. ICC ranged from .92 (COPD) to .96 (healthy subjects). In COPD significant correlations were found for pPTT R-S, Q-S and R-D with RV E`, (all > ρ: .49, < p = .0364), pPTT R-S, Q-S with RV E/E` (both > ρ: .49, < p = .0291), pPTT Q-S with RV S´ (ρ: .58, p = .0134), RV A (ρ: .59, p = .0339) and heart rate > ρ: -.39, < p = .0297). pPTT R-S, R-D showed significant correlations with FVC predicted (%) (ρ: .48 p = .0224) and FVC (l) (ρ:.47 p = .0347).
Conclusions:
All pPTT measures exhibited high reproducibility. In COPD patients pPTT measures correlate with diastolic right ventricular function. Defining Q as starting point seems clinically advantageous considering electromechanical desynchrony in patients with conduction disorders.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Special considerations while measuring pulse
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Measurement of Blood Pressure