Objectives:
A primary reason for the low adoption of hearing aids (HAs) among the large population with sensorineural hearing loss is the perception that these devices may negatively impact remaining hearing ability. Research addressing this issue has yielded conflicting results. This study examined the long-term effects of HAs on standard audiometric changes in individuals with sensorineural hearing loss.
Methods:
We retrospectively analyzed patients who acquired unilateral HAs between 2015 and 2017 and demonstrated consistent use over a 5-year period. We examined demographics, medical comorbidities, audiometric data, and questionnaire results from the Hearing Handicap Inventory for the Elderly and the International Outcome Inventory for Hearing Aids. Additionally, we reviewed each patient's history of noise exposure and prior HA use.
Results:
The study included 55 patients who used unilateral HAs, with a mean follow-up period of 5.32 years. Among them, 31 patients (56.4%) used the HA on the right side. Audiometric data from the aided side showed no significant difference from the unaided side in either the pre-fit pure-tone average of air conduction (AC) or word recognition score (WRS) (P =0.73 and P =0.11, respectively). Similarly, no significant differences were noted in the 5-year follow-up audiometry of AC and WRS (P=0.98 and P=0.07, respectively) or in the change from pre-fit to final audiometry for either parameter (AC, P=0.58; WRS, P=0.70). Eleven patients (20%) exhibited a deterioration in hearing (as measured by AC) of 5 dB or greater on the aided side compared with the unaided side, while 23 (53.5%) showed greater WRS deterioration on the aided side. No significant factors were found to contribute to the difference in hearing deterioration between groups for either AC or WRS.
Conclusion:
No significant factors were identified as contributing to hearing deterioration after prolonged HA use. Overall, the use of HAs did not adversely impact residual hearing.
Related Concept Videos
Perception of Sound Waves
The pitch of a sound depends on the frequency and the pressure amplitude of the source. Two sounds of the same...
Hearing
Anatomy of the Ear
Auditory Pathway
When viewed cross-sectionally, the cochlea reveals the scala vestibuli and scala tympani flanking...
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Unrenewable Cells
Photoreceptors
The retina is composed of several layers and contains specialized cells called photoreceptors. The photoreceptors (rods and cones) change their membrane potential when stimulated by light energy. There are two types of photoreceptors—rods and cones—which differ in the shape of...