Related Experiment Video
Updated: Jun 27, 2025

Author Spotlight: Development of a Smartphone-Enhanced Paper-Based Device for Rapid Dengue NS1 Detection
Published on: January 26, 2024
Development of pectin-based gel electrolyte for wireless electrochemical determination of cadmium and lead using
Nantanat Lersanansit1, Kingkan Pungjunun1, Orawon Chailapakul2
1Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok, 10330, Thailand.
Abstract:
A portable device offering effortlessness, mobility, and affordability for real-time and on-site monitoring of heavy metals is currently in great demand to maintain environmental sustainability. Herein, a platform utilizing a biopolymeric gel-based electrolyte for the on-field simultaneous determination of Cd(II) and Pb(II) is described. Pectin, a natural polymer, was exploited as a chemical delivery medium on account of its biodegradability, environmental friendliness, and rapid dissolving characteristics. The gel electrolyte was prepared by having pectin dissolved in KCl mixed with Sb(III)-Bi(III) bimetallic alloy solution, and casted onto a paper substrate. An in situ bimetallic alloy and pre-mixed bismuth nanoparticles modified screen-printed graphene electrode (Sb-Bi/BiNP/SPGE) were employed to enhance the electrochemical signals of Cd(II) and Pb(II) for the differential pulse anodic stripping voltammetry (DPASV). It was demonstrated that the platform was capable of generating sharp and well-defined current signals, achieving the low detection limits of 50.98 ng mL-1 for Cd(II) and 40.80 ng mL-1 for Pb(II). The reproducibility, as indicated by the relative standard deviation, was found to be less than 10.4 % (n = 10) for the developed gel-based device when coupled with a wireless near field communication (NFC) potentiostat. Lastly, the obtained sensor was applied for quantification of Cd and Pb in potentially contaminated groundwater samples. The recoveries obtained were satisfactorily within the acceptable range. The newly designed platform exhibited several advantages, including small sample volume (μL), low-cost, no sample preparation requirements, and being environmentally friendly. The convenience of a portable device utilizing the proposed biopolymeric gel-based electrolyte for on-field analysis makes it highly appealing for various applications.
Related Concept Videos
Potentiometry: Membrane Electrodes
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...

